boiler supplier

1000 bar natural gas fire firetube boilers information

Gas oil furnace and expansion tank should pay attention to what effect the high slot: the gas oil furnace, I believe we will not feel strange, but should also have a certain degree of knowledge and understanding, if the box has been concerned about the 1000 bar fire firetube boilers information site, and at the same time to carefully read the relevant article, and at the same time, to grasp their knowledge of words. So, based on this, then, we will continue this work, to promote a good learning process of the product, and so that everyone from a new harvest and inspiration. 1. Gas conducting oil conducting oil furnace exhaust port, which is typically what position the boiler on? HTF HTF furnace gas exhaust port, generally speaking, at the top of the boiler, i.e. high boiler shell. Furthermore, in this site, as well as the seat member, it is mainly used to install safety valve. Moreover, this drawing on the boiler, also will be marked out, as long as you can read drawings, you can, so can avoid making mistakes. 2. Gas expansion slot conducting oil furnace, which is in use, should pay attention to what issues? Gas expansion tank of oil furnace, the origin of their name, in part because of the boiler will heat transfer oil into the expansion slot, the expansion play a role. And this means that during erection, caution needs to be done is, it can not be damaged or broken. In addition, the oil level in the expansion tank, should be well controlled, so as to ensure the normal operation of the boiler.

How to set the height of the 1000 bar fire firetube boilers information chimney

The coal fired boiler can be divided into two kinds:vertical boiler and horizontal boiler. And the horizontal boiler is very economic because of its long flue gas flow, slow smoke discharge, high heating efficiency. So it is widely sued in the market. After buying a boiler, it is necessary for them to build a boiler room,in the installation the height of the chimney also need to pay attention. According to the ZG engineer, the chimney height should be accordance with the lowest height of GB13271-2001 stipulation. Only one chimney is allowed in a boiler room. The specific requirements was listed below:

1.When the boiler’s output capacity is more than 1t/h or 0.7MW, a permanent thief hatch and relevant facilities should be setted in compliance with the stipulations of measuring method for smoke and dust of boiler emission, and The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source.

2. The exit diameter of the chimney should be not lower than the largest load. The smoke flow should not be too fast. when the load of the coal fired boiler is at its lowest level, the velocity of the chimney exit should not lower than 2.5~3m/s.

3. If the chimney heat does not reach the height of the above stipulations, the maximum discharge concentration of the dust,sulfur dioxide, nitric dioxide should be carried out at 50% of the corresponding area and time emissions standard .

Operation of the gas 1000 bar fire firetube boilers information has what measures? Gas-fired boiler in many large factories or companies which, basically is a kind of device can see, of course, such a device is actually in the process of actually running, more or less have some of their own operating standards, from the current situation, when they run have more to do security measures. So what are run gas boiler measures at run time? (1) After a series of gas-fired boiler inspection, maintenance, basically in the process of running to them in accordance with the relevant requirements to run, there will have a lot of protection, even if they want to determine the importance of the protection of the entire work. (2) gas-fired boiler in the process of ignition, more or less likely to occur will require some regulations, such as they might meet some of the fuel, but the fuel pressure in the whole process of evaporation or mist, more or less will meet some of stroke, some extent, when the entire examination will also return to substantially a normal state, they energize the disable signal is short, when the flow rate of the whole is greater than a single second branched oil gun 0.65 kg when it should launch this gun running. (3) gas-fired boiler at the time of ignition, be sure to pay attention to look at all of the furnace temperature, the temperature inside look at the major, and the entire main steam pressure in the process of rising more or less there will be some obvious favoritism, or the case of speech do not rise, so then we should immediately go to the examination of fire tank. in addition, if found throughout the fuel into the furnace did not catch fire, it would tightly shutdown.

To further reduce emissions of air pollutants and improve air quality of the environment, the Shanghai Municipal People's Government Office issued the "Opinions on accelerating the transformation of the city mentioned standard 1000 bar fire firetube boilers informations of small and medium" (hereinafter "Opinion"), to accelerate the introduction of Shanghai City small boilers mentioned standard transformation respond positively.

Before the end of 2018, the district in conjunction with boilers and industrial distribution block, complete the development and revision of the Gas Pipeline Network Planning in this area. City, district authorities, according to the unit Gas Pipeline Network Planning and excavation plan, speed up the construction of natural gas pipeline network.

Variety of boiler fuel to replace natural gas, natural gas pipeline network (municipal pipe network to users outside the red line pipe) 50% of the cost of laying borne by the gas company; the remaining 50% by the district government and users each pay half, and encourage qualified district to provide more support. On the outskirts of the gas pipeline construction is temporarily unable to reach enterprises in the region, while ensuring security compliance cases, it can be in the form of non-natural gas pipeline, and implement an orderly transition after the completion of the pipe network. Encourage alternative gas supply business enterprises to provide gas price discount for the gas boiler.

10KV for the implementation of alternative electric boiler, 35KV and other business expansion project, to which the power supply capacity of the electrical part of the boiler, according to the city's non-resident business expansion project quota standards, engineering fees charged by half.

Environment departments to strengthen law enforcement and inspection of boiler units, fuel use, operation and maintenance, equipment maintenance, inspection, non-functioning facility once found, according to the law severely punished; at the same time, strengthen supervision and monitoring, if it is found excessive emissions, according to law strict punishment.

Boiler units and boiler mentioned standard transformation service units bear the main responsibility for the boiler safety issues involved. Site construction unit must have the appropriate boiler manufacture or installation (reconstruction) qualification, boiler commissioning personnel must have the appropriate special equipment operator certificate. Prior to the construction site mentioned standard boiler units to implement the transformation, boiler location should be informed in writing of special equipment regulatory authorities.

The district government is the responsibility of the main boiler to mention the transformation of the standard, according to the "ground principles" to promote the transformation of the boiler. Combined with the actual circumstances of the district reform implementation plan, accelerating the construction of facilities to ensure timely completion of the task of transformation, to ensure that policies and financial support in place.