boiler supplier

10tons steam chain grate stoker boiler

Premix low nitrogen condensing 10tons steam chain grate stoker boiler characteristics ① power 550kw, 700kw, 1100kw. ② The premix condensing technology, air-fuel ratio is more reasonable. ③ The silicon aluminum alloy heat exchangers, high heat transfer efficiency and corrosion-resistance. ④ High efficiency: thermal efficiency of up to 108% (water 50 ℃, backwater 30 ℃). ⑤ Low Emissions: N0x emissions up to 30mg / m3 or less (standard conditions). ⑥ microcomputer intelligent control, the operation more convenient. ⑦ stable operation: adoption of the European advanced accessories to ensure safe and reliable operation. Ease of installation and transportation ⑧: small size and light weight. ⑨ low maintenance costs.

Since "strong piece autumn and winter air pollution in a comprehensive way, determined to win the Battle of Hebei blue sky" press conference was informed, Hebei Province, to make arrangements for winning the Battle of the blue sky, requested the preparation of implementation of the blue Battle Hebei Province Government Information Office held three-year operational plan and cleaning winter heating three-year plan to ensure that changes every year, three years, a large bear fruit.

Really good job of air pollution prevention and control work in the past year, Hebei Province, adhere to the scientific governance haze, collaborative governance haze, haze iron-fisted rule, will coordinate development of pressure energy, reduce coal, running enterprises, dust, vehicle control, by Green et key tasks, play a set of tackling the problem, the main root of the problem "combination punches." Where the complete substitution of gas for coal, electricity-generation coal transformation 2,537,000, Yajian steel production capacity of 27.54 million tons, 21.32 million tons of iron, coke 8.088 million tons, 10.68 million tons of coal, Reconstructing "scattered dirt" Enterprise 38785, off stop banned enterprises 68747, the new afforestation area of ​​741 hectares. At the same time, also launched a special inspection of law enforcement inspectors and four comprehensive management of air pollution, to carry out unannounced visits to check the dark, spot checks, cross-law enforcement, road law enforcement to crack down on environmental violations, and earnestly solve the "last kilometer" problem.

Director, Office of Atmospheric Hebei Province, the provincial Environmental Protection Bureau Director Gao Jianmin, said: "This year we will develop science of air pollution control 3-year operational plan, a clear timetable, route map, to promote the key cities 'insurance bottom line, back ten' focus on tackling to ensure that air quality 'changes every year, three large effective', and strive to Shijiazhuang, Hengshui, Tangshan City, the first exit after ten. we will actually improve air quality and enhance, to better respond to the concerns of the masses, improve people's livelihood well-being, and enhance people's sense of well-being obtained. "

Run standard gas hot water 10tons steam chain grate stoker boiler you know? Run standard gas hot water boiler you know? A. Each boiler must be automatic ignition process. II. Safety device for each boiler must ensure reliable, including flame protection, gas overpressure protection, over-temperature protection furnace, ultra-low water level protection. III. According to state regulations safety valve to send technical supervision departments for inspection once a year. IV. Each boiler installed system should ensure reliable and accurate pressure gauge and check them regularly. V. The conditions of this building system, the operation to ensure that water pressure ≧ 0.10Mpa, to ensure that water pressure ≧ 0.08Mpa, and to ensure adequate water pressure. Six temperature requirements: (1) the outlet temperature of the boiler does not exceed 85 degrees Celsius. (2) According to the heating season should ambient water temperature regulating system, to set the system temperature trap temperature is valid, the steady heat, water temperature not less than 50 degrees at night, daytime temperature reached 55; 60 degrees Celsius. (3) Heating temperature of the daytime running balancing tank is not less than 60 degrees Celsius, 55 degrees Celsius temperature not lower than the temperature over night balancing tank is not less than 55 degrees Celsius, at a temperature not lower than 50 degrees Celsius. According to ambient temperature, at any time to adjust the operating temperature. Seven boiler water requirements: (1) the operation of the furnace is not less than the water pressure 0.8bar. (2) system to timely pay, the minimum water pressure of not less than 0.08Mpa. (3) normal discharge, gas discharge, the normal equipment and systems to ensure reliable. (4) water treatment to standards, water quality testing report should be filed. VIII. Gas inlet pressure should ensure 100Kpa to 110Kpa, whereby pressure to clean inlet filter and setting the gas pressure from the hive property management network. IX. Boiler room ventilation should be regularly and ensure clean environment and equipment. Run standard: a must for each boiler with automatic ignition process. II. Safety device for each boiler must ensure reliable, including flame protection, gas overpressure protection, over-temperature protection furnace, ultra-low water level protection. III. According to state regulations safety valve to send technical supervision departments for inspection once a year. IV. Each boiler installed system should ensure reliable and accurate pressure gauge and check them regularly. V. The conditions of this building system, the operation to ensure that water pressure ≧ 0.10Mpa, to ensure that water pressure ≧ 0.08Mpa, and to ensure adequate water pressure. Six temperature requirements: (1) the outlet temperature of the boiler does not exceed 85 degrees Celsius. (2) According to the heating season should ambient water temperature regulating system, to set the system temperature trap temperature is valid, the steady heat, water temperature not less than 50 degrees at night, daytime temperature reached 55; 60 degrees Celsius. (3) Heating temperature of the daytime running balancing tank is not less than 60 degrees Celsius, 55 degrees Celsius temperature not lower than the temperature over night balancing tank is not less than 55 degrees Celsius, at a temperature not lower than 50 degrees Celsius. According to ambient temperature, at any time to adjust the operating temperature. Seven boiler water requirements: (1) the operation of the furnace is not less than the water pressure 0.8bar. (2) system to timely pay, the minimum water pressure of not less than 0.08Mpa. (3) normal discharge, gas discharge, the normal equipment and systems to ensure reliable. (4) water treatment to standards, water quality testing report should be filed. VIII. Gas inlet pressure should ensure 100Kpa to 110Kpa, whereby pressure to clean inlet filter and setting the gas pressure from the hive property management network. IX. Boiler room ventilation should be regularly and ensure clean environment and equipment.

Effects of changes in vapor pressure heating 10tons steam chain grate stoker boiler steam temperature change on the stove vapor pressure of the steam temperature: Usually when the steam pressure is increased, the superheated steam to rise. This is because when the vapor pressure increases with an increasing saturation temperature, from water into steam need to consume more calories in the case of the fuel constant, the instantaneous evaporation of the boiler to reduce, i.e. the superheater by reducing the amount of steam, the steam is increased relative to heat absorption, resulting in superheated steam temperature.

Related Information