boiler supplier

24mv low pressure boiler applied in school

For the inspection of steam 24mv low pressure boiler applied in schools features the hotel laundry room in hotels of clothes to be cleaned for the guests, but also the need for bed cloth, towels and other cleaning, need to use a lot of laundry facilities. Most of these devices are applied to the steam demand, so the hotel laundry room often needs to have steam boiler. Henan fast boiler for the inspection of steam boilers have the following characteristics in the use of the hotel's laundry room: 1, steam room, hotel laundry equipment is usually saturated steam of 0.4 ~ 0.6MPa. Use temperature of the steam demand is not very high. 2, steam room, hotel laundry equipment as long as the laundry when open, not open without washing. It is required to have a quick steam boiler steam production can start. Opening the laundry equipment is sometimes more or sometimes less, so the demand for steam boilers can be adjusted within a certain amount of steam range. 3, the hotel's steam boiler reasons so demand for operating costs of the steam boiler with high thermal efficiency, in order to save operating costs. 4, the hotel's area is relatively limited, so choose a smaller footprint steam boiler. 5, in order to control heat and steam pipes investment capital loss, usually steam boilers are placed in the laundry room on the edge.

Before a cooperation with the parties, we heard from other companies where fast 24mv low pressure boiler applied in school brand, saying it was so fast square product quality, use a long time, and after-sales service is also very complete. After the collaboration found that it really is a well-deserved reputation. This three boilers put into use, not only reduces emissions, while meeting the needs of normal heating, fuel input has also been reduced, as we save a lot of operating costs. --customer feedback

CFB 24mv low pressure boiler applied in school which has the good performance and high reliability is deigned and manufactured according to the civil and abroad CFB boiler’s design, manufacture and operation’s successful experience mixed with the our ZG’s specific characteristics. The water system is natural circulation system and the boiler adopts the whole airproof high temp. Cyclone separator whose features are high separating efficiency and reliable operation.

Industrial 24mv low pressure boiler applied in school stoker boiler overpressure personnel, Water Shortage Accidents treatment of industrial boiler stoker boiler overpressure personnel, processing method 1 Water Shortage Accidents, industrial boiler overpressure accident occurs boiler overpressure accident is due to the actual operation of the actual boiler pressure value exceeds the maximum working pressure caused. Boiler overpressure accident is an accident the most common accidents. Overpressure characterization: the boiler is running, when the pressure in the boiler is too high, the air pressure will be significantly increased, exceeding the safe working pressure of the boiler, boiler safety play a proactive action; boiler overpressure alarm will issue a warning signal; steam temperature rising Wait. Common causes of boiler overpressure are: gas fault does not operate normally with gas; valve failure, equipment failure alarm; relates to a boiler because defects result buck during use, the cross-sectional area of ​​the exhaust valve is not adjusted , still use the original terms of safety valves. Processing overpressure accident. Found boiler overpressure should be reduced combustion; if the boiler safety law does not work, can take artificial exhaust, or located vent valve on the boiler open for exhaust, to adjust the pressure of the boiler; maintaining an internal boiler water level is normal, reduce oven temperature; the oven before deciding to stop or resume operation, check the cause of the boiler overpressure and damage the furnace. 2, industrial boiler water accidents occur during use of the boiler, the boiler water shortage accident was mainly due to the boiler water level below the safety level. Boiler water often leads to additional boiler superheater heating surface tubes cause deformation even wave train; mouth off or leakage; boiler wall is damaged. In the use of the boiler, the boiler water accidents can not be properly resolved, will often bring very bad consequences, causing serious damage. During the accident boiler water treatment, we must first determine the severity of the accident boiler water, and then select a reasonable solution. When the boiler water accidents judge, the method used is called the water. The specific workflow is put cock open water table, water vapor union and even the water pipes were flushed, the union says is the subject of steam cocks closed, while closing the drain cocks. If the water level in the table who is appears, the boiler water shortage accident as minor, if there is no water in the water table appears, the water level has dropped to even lower water level or water pipes, which shows a serious lack of water boiler accident. Sheung Shui to be a slight lack of water in the boiler immediately when an accident occurs, to ensure that the water level in the boiler at normal levels. If by Sheung Shui, the water level in the boiler water level is still not back to normal, we need to conduct a comprehensive inspection of the boiler. When the boiler severe lack of water, the boiler must stop work.

Related Information