boiler supplier

300 psiwaste heat recovery boiler

We have long known that fast 300 psiwaste heat recovery boiler this brand, high-tech enterprises in Henan Province, the most influential brand, technology entrepreneurs contribution to enterprise and many other honors, so that our brand is very interested in each other fast. Through this collaboration, proving once again that our decision is not wrong, 15 tons of steam condensing gas boiler provides steam to fully meet the needs of our dairy products processing plant. --customer feedback

Method: 1, first, the pickling operation is started, the 300 psiwaste heat recovery boiler economizer, in addition to filling the drum with brine and water wall. 2, the ignition operation of the boiler, the boiler when the temperature rises to 70-80 deg.] C, the boiler flame, pickling may be performed thereafter. Before pickling, but also with superheater backfilling demineralized water, until the water until the overflow into the drum, to prevent the acid or acid-introduced into the superheater steam damage. 3, when the acid charged to the boiler, in any case, should not be firing boiler. Drum discharge hole and the other should be opened to discharge the generated acid and iron reaction of hydrogen, hydrogen has dissipated before sure to avoid the use of open flame or electrical sparking device to avoid risk of explosion of hydrogen. 4, finally, after the completion of filling the acid, so that the boiler economizer and soaked in the solution for about 6 hours, and then the acid is discharged, and rinsed with demineralized water superheater. Acid discharged after the acid drained, operating boiler feed pump, a water economizer capacity charged boiler feed water shut-off valve to prevent leakage.

Routine maintenance programs which have low nitrogen 300 psiwaste heat recovery boilers both in thermal power generation, industrial or domestic heating, low nitrogen boiler in this field are the role should not be underestimated. Quality low nitrogen boiler is not only safe, low emissions, but also has ultra-high thermal efficiency, each winter home heating good helper. Many people wonder how routine maintenance of the boiler were low nitrogen, the following is a simple solution to this problem: a periodic inspection device under normal load conditions, the boiler is running low nitrogen generated noise and exhaust gas temperature are small, low, users may use this as a basis for screening, detection of boiler operating conditions. Many devices after a long continuous operation, the situation will have efficacy as before, the reason is simply too large load carrying device sake. The face of such a situation, the user needs to use the time strictly controlled within a reasonable range, or see through the current stable situation, if you need to stabilize timely maintenance shutdown in order to reduce boiler load. Second, the use of reasonable method of cleaning a boiler in addition to the regular inspections load condition, for the protection of low nitrogen boiler has a longer life, need to be cleaned regularly, in particular using a reasonable method. First, the alkali agent may be used for a long time into the boiler to boil; Second, the acid liquid can be configured to use cleaning; Third mechanical cleaning may also be used. If after this three methods with the use of the development cycle, but also to achieve a better effect of decontamination detergent. Third, the maintenance of good water quality management observant user will make the boiler from outside to inside, and therefore, the maintenance of low nitrogen boiler burner correspondingly inevitably go to the water contained in the management of the furnace from the examination. If the boiler water concentration is too high, it will lead to false water level phenomenon, resulting in the boiler does not work. Therefore, users need to strengthen water quality management, so that preventive measures, so it is more conducive to long-term maintenance of low nitrogen boiler. That is, for the above-mentioned types of Low - NOx boiler routine maintenance, quality worthy of preferential treatment by the boiler equivalent, thus requiring the user with care in daily life, proper management, its maintenance work to be the best. At the same time, it is also where to buy quality low nitrogen boiler troubled customer, I propose to resolve by asking the store or access to low nitrogen boiler sales ranking, etc.

4 tph SZS condensing gas-fired 300 psiwaste heat recovery boiler in AnhuiThe production of rubber outer layer of the wire and cable must through a vulcanization process, and the vulcanization process needs steam from boilers to heat and pressure the rubber. Anhui Cable Group is an enterprise specializing in the production of wire and cable. It mainly produces and operates 1E class K2, K3 and non-1E medium voltage power cables, various types of flame retardant and refractory special cables. In 2015, the principal of Anhui Cable purchased 4 tph SZS condensing gas-fired boiler in ZOZEN boiler to provide steam for rubber vulcanization. The steam temperature was required to be between 140-180℃. After vulcanization, the natural cooling was performed, opened the valve, the steam condensate in the pipeline will go directly into the cooling pool. After steam cooling, fresh water can be added to the processed of drawing, annealing, water sealing, extruding, extruding rubber, mixed rubber, desulfurization and dust removal, which saves a lot of production water for the company. In addition, ZOZEN’s boiler adopts high-quality aluminum silicate fiber and equipped with fire-resistant mud insulation. The temperature of boiler body can be controlled below 45℃ to effectively control heat loss.

Related Information