boiler supplier

450 pump power electric vertical steam boiler

4295, Henan reasons gas 450 pump power electric vertical steam boiler chimney white smoke and some will Henan gas boiler chimney white smoke, some Henan gas boiler chimney does not smoke because of wet dust removal equipment used. Large water content of the flue gas. If the rear of the boiler flue temperature is too high, it will produce water vapor. Dry type cyclone. If the boiler air distribution adjustment is not the time. Excessive air excess factor. Short residence time in the furnace flue. The exhaust gas temperature is too high. Smoke density and air density difference is large. It may produce a visual image of white steam plume. The truth is like the summer heat flow on the same asphalt. Henan gas boiler includes a gas water boiler, gas hot water boiler, gas steam boilers, gas hot water boiler which is also known as gas heating boilers and gas boilers bath, as the name suggests refers to the gas boiler fuel gas boiler, gas boilers and oil-fired boiler , compared to the most economical electric boiler, so most people have opted for a gas boiler as steam, heating, boiler equipment for bathing.

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two 450 pump power electric vertical steam boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.

Nine hot water 450 pump power electric vertical steam boiler technical characteristics of electric water boiler 1, the hot water boiler electric water boiler hot water boiler microcomputer controller, the built-in backlight in the LCD screen display, operating status of the boiler clearly visible. All operations are easily accomplished by simply buttons, super boiler display controller, the control function is complete. 2, a ceramic tubular electric heating hot water boiler uses water and electricity separation electrical heating mode, the complete separation of the tubes and electric heating boiler water, boiler safe and convenient maintenance, replacement of a heating tube; stainless steel tube electric heating type hot water boiler implementation immersion electrical heating, water heating furnace, high efficiency, and the heating furnace tube flange connection, easy to clean, replace them. 3, the user can arbitrarily set the temperature between 30 ℃ -90 ℃, the boiler in accordance with user requirements timing, temperature, or automatic circulation heating system to provide users with a bath heating, domestic hot water. 4, high-power stepping boiler heating control law input sharing group, the group can be randomly put into or heating is stopped according to the load variation, and significantly reduce the impact on power. You can also manually start and stop the heating section number, user side to adjust the power boiler itself. 5, the control system controls the circulation pump start and stop in accordance with the temperature of boiler water. Hot water circulating pump is stopped when the furnace temperature reaches an upper limit, below the hot water circulation pump start lower limit temperature. 6, bath, living with the embalmed internal hot water boiler, furnace rust corrosion, long service life of the boiler, hot water, clean water, sanitation. High centrifugation using glass fiber cotton multilayer insulation, heat loss, energy saving; famous white color board packaged, elegant appearance corrosion resistance. 7, the boiler having a leakage protection function (power supply control system detects electrical leakage, automatically cut off the power boiler), anti-dry protection low water level (the water level is below the minimum limit of the level set immediately stop and alarm), the furnace overheating protection function (start when the boiler shell temperature exceeds 105 deg.] C, immediately shut down and an alarm, the temperature of the normal automatic boiler), the temperature sensor protection function (control system keeps detecting sensor condition, stop immediately and alarm), the power supply voltage protection function (when the power supply is abnormal, the automatic power-off. after the normal, automatic recovery operation), the heating assembly phase protection function (monitoring phase after heating assembly, shutdown protection). 8, the top of this boiler has a vent to the atmosphere, the interior is not under pressure, boiler work at atmospheric pressure, there is no risk of explosion, the complete elimination of security risks. 9, a back outlet symmetrical design (double inlet) for quick connection installation; boiler mechanical and electrical integration, compact size and reasonable transportation is very convenient. When natural gas steam boiler for emergency shutdown? Emergency shutdown is an emergency action to take when natural gas steam boiler accident, in order to prevent the accident from being taken. When the boiler in operation, any of the following circumstances, should immediately shutdown: ① boiler water level below the lower edge of the visible water table, increasing water supply and other measures, but the water level continued to decline; ② boiler water level exceeds the maximum visible water level (full of water), the water drainage can not be seen; ③ all fail to pump failure or water supply system, not water to the boiler; ④ water gauge or all of valve failure; ⑤ boiler element damaged, thereby endangering the safety of operating personnel; ⑥ other unusual circumstances endanger the safe operation of the boiler. In case of power, water supply and other emergency situations should take timely measures. If not solved, it should be promptly reported to the company. Prohibited under pressure boiler water temperature or higher, the repair of boiler pressure element, to prevent the steam, the water discharge was wounded. Under repair equipment, to hang warning signs. Electrical equipment repair, electrical work should be carried out staff. If in vapor, flange and pipe joints, safety, staffing holes and inspection visits to check the hole, etc., should not be in front, but should side. The operation should wear protective gloves to prevent burns. The operator should make regular automatic (at least once every three months) and manual exhaust (at least once a week) to check and ensure that sensitive and reliable safety valve.

Components of the gas steam 450 pump power electric vertical steam boiler There are several both production and life, we often gas steam boiler is used, and therefore the author gave us sort out what the associated structural gas steam boiler. First, the blowing apparatus: the blowing device placed inlet filter, through the use of extraction air blower burner was added to achieve an amount of change fire. Second, the water pump: main condenser is pumped from the water softener is then added to take thermal efficiency steam boiler flue gas emissions caused by water once preheated. Third, the fuel gas system: an interface comprising natural gas, burner, natural gas adjusting means. Fourth, the protection valve: placing a certain pressure value, higher than the preset value independent relief. Fifth, gas steam boiler electric control system and other in front of these two would certainly be an integral component of a gas steam boiler, assumptions made when the boiler water quality standard deviation, is not to turn the boiler, should pay close attention. At the time of manufacture, and should always check the gas steam boiler maintenance, maintenance inspection time for serious recording, only careful and thorough use, unswerving overhaul inspection, to be able to increase production efficiency to a greater extent, not only negative results can occur .

Related Information