boiler supplier

aquecedor a gas com boiler

1. Gas fuel used in oil and gas aquecedor a com boilers

Gas-fired steam aquecedor a com boiler safety valve from installation to use, it must remain vigilant safety valve is one of the most important components of the gas steam boilers, boiler probability of the risk occurring due to various incidents can effectively suppressed. This article focuses on the safety valve from installation to use several important considerations, we do not ignore the use of gas when it steam boiler. A Notes 1 safety valve, the safety valve should be mounted vertically in a high position in the pot business, set box. 2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly. 4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm. 5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve. 6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. 7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve. 8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve. 9, separable economizer outlet, the steam superheater outlet valve must be installed.

Hot water aquecedor a com boiler is one of the important equipment for the district to provide our real estate company, and two gas hot water provide the fast boiler boiler flotilla of environmental performance, in full compliance with state regulations after smoke was detected in the rear of the boiler. And boiler operation is safe, stable, we use the very at ease. --customer feedback

Gas-fired steam aquecedor a com boiler and gas steam boiler at any time there is any good compared to the country more and more attention to environmental protection, gas steam boiler has been a great blow, and relatively gas steam boiler by many users of all ages, in recent years, the country also strongly promote the use of gas-fired boiler, gas steam boiler then compared with the gas steam boiler what good is it? And today we work together to explore. Gas-fired steam boiler steam boiler and gas each accounted for half of the market, showing potential rival, but in the long run, gas steam boiler will obviously be the only dominant market. Do not believe, look! 1. Purchase costs: gas boiler is evident in the technical and auxiliary facilities are far ahead of the gas boiler, and it is equipped with a special gas burner. 1 steam boiler tonnage, for example, the price of gas than the gas boiler boiler on high about 30%. 2. Construction costs: The costs mainly from the boiler room. Because the corresponding auxiliary equipment more gas steam boiler, the boiler room in the building have a little more money. The gas boiler auxiliary facilities require little or automatic control and operation, and automatic alarm and automatic protection, not only save building costs, but also safe and reliable; Also connected to the gas pipeline, the burner will automatically supply gas can effectively save costs staff. The gas-fired boilers because of the need of coal on the program, so it needs some staff payroll. 3. Fuel cost: around this by looking at the actual specific fuel price can be clearly seen. The fact is that the amount of gas than the gas burned per hour for much more. 4. environmental costs: in the need to protect the environment, review the current gas boiler more strict. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used.

Related Information