boiler supplier

blown gas waste heat boiler in philippines

Chinese Academy of Engineering, pressure vessel and pipeline safety director of the National Engineering Research Center, Dean of Hefei General Machinery Research Institute Xuedong academician and we work together to build this high-tech cooperation platform. Xuedong academician in the academic reputation, outstanding talent in the field of technology transfer pipeline.

Many companies need to use blown waste heat boiler in philippiness, and oil and gas boilers are a very common type of boiler. How to use oil and gas boilers?

Chemical prevent high temperature corrosion of blown waste heat boiler in philippines waterwall boiler chemical improvements to prevent high temperature corrosion improvements waterwall 1, using an anti-art windshear main principle is offset by a spray angle of air flow injection port, and the original jet forming a motion , the opposite direction of rotation, in tangentially running smaller diameter, due to the opposite running direction of the initial movement of the main gas flow direction of the gas flow in the furnace after the anti-wind shear, the pulverized coal injected hindered high-temperature air upstream of the primary air flow and the time, the pulverized coal injection speed is reduced rapidly, enhancing coal dead time in high temperature zone, to enhance the combustion efficiency of pulverized coal. By using an anti-wind shear can effectively prevent high temperature corrosion phenomena, and can enhance the ability to stabilize combustion in the boiler furnace, reduced coke boiler case, as shown in FIG. 2, using the technology of Side by side wind technology is mainly on the high temperature zone waterwall corrosion or high temperature corrosion installed upstream of the injection port area, and ejecting the air in the furnace boiler. Technology is mainly employed side air can be controlled in the high-temperature reducing gas corrosion area, enhanced oxygen content in a local range. 3, to improve the control operation to take excess air coefficient increases, a plurality of coal mills is not put into operation at the same time, reduce the coal particle size, increase the air preheater ash fouling preventing plugging of equipment and operation control systems such as high temperature measures to prevent High temperature corrosion phenomena.

How to maintain the blown waste heat boiler in philippines shutdown? After boiler shutdown cooling, heating surface must be thoroughly cleaned of fouling and ash grate the upper, the lower portion of the furnace. Then to maintain a certain degree of natural ventilation flue. In general, in order desiccant moisture should be placed in the furnace, flue. The quicklime as a drying agent, within the furnace or flue gas per cubic meter should be placed generally about 3kg. After placing all the ventilation should be tightly closed doors. After the change of lime powder to be replaced. Low-lying position as boiler room, ground during shutdown severe flood tide, often approach should be used and placed a small fire to dry desiccant combination. How to care? If the boiler shutdown a long time, the boiler shutdown after complete removal of soot coated with an anti-corrosion red lead paint in oil or other metal surface furnace. As internal corrosion Maintenance shutdown of the boiler body, under normal circumstances, can be used wet shutdown maintenance is not more than one month, one month electrically operated steam boiler should be taken to dry more maintenance. To note the following problems when a dry maintenance: desiccant boiler not in direct contact with the metal surface, may be mounted in a container such as the iron plate after the desiccant is placed, and a hole for shutting the other hand hole cover.

Related Information