boiler supplier

changing industrial black oil boiler to gas

Boiler installation of "blast doors," What is the role now on the market most of the changing industrial black oil boiler tos to gas, oil, biomass, electricity as the main fuel, coal-fired boilers because of its harmful pollution levels gradually been changed or replaced. In general, no boiler explosion during normal operation, but if it is due to the improper operation of the ignition or operation, it may cause the furnace or tail or secondary combustion flue explosion, resulting in serious danger of impact. In this case the role of "explosion vent" is manifested when the furnace or flue trace knocking occurs, the pressure within the furnace is gradually increased, when a certain value is higher than the pressure relief device can turn on itself through the explosion vent to avoid the risk expansion to ensure the overall safety of boiler and furnace wall, more importantly, it is to protect the safety of the boiler operator. Currently there are blasting boiler membrane and two kinds of swing-proof door. Swing-proof doors are mostly placed in the furnace wall of the combustion chamber. Their installation position can be divided into vertical and tilting, by the door frame, the door and the hinge member and the like components. The door frame and multi-cast iron round or square, the width of their mutual contact surface generally is 3 ~ 5mm, and to ensure seamless tight. The door is coated with a heat-resistant concrete, which limit the pressure according to a desired thickness value has been calculated or determined experimentally. When the gas in the furnace or flue explosion, the door is automatically turned about the shaft relief, and then shuts itself down. Sealing pressure of the vent door from the inclination angle (usually not more than 30 °) or the downward pressure created by the weight of a weight is obtained. Most membrane blasting explosion vent means on the flue, and a clamping device consisting of explosive membrane. Bursting disc is typically made of a thin metal plate of asbestos, aluminum and stainless steel. When an explosion occurs in the furnace or flue gas generated shock wave pressure to bursting membrane damage, play the role of relief, once the explosion vent membrane after blasting effect, it will not reset itself, the clamping device must be open blasting repositioned membrane. Note 1, the position of general device explosion-proof door on the wall or on top of a steam boiler furnace furnace exit side of the furnace flue fuel gas. 2, explosion-proof doors should be installed in place without the threat of operator safety, and a pressure relief guide tube, it shall not be stored near inflammable and explosive materials, highly preferably not less than 2 meters. 3, activity blast doors require regular manual test to rust dead.

Natural gas as a clean energy, can be reduced nearly 100% of the sulfur dioxide and dust emissions, 60% of carbon dioxide emissions and 50% of nitrogen oxide emissions, and help to reduce acid rain, global warming alleviate, reduce proportion of the amount of coal energy important energy; corresponding gas changing industrial black oil boiler to has gradually been used and popular.

Four coal-fired changing industrial black oil boiler tos precautions to meet a variety of fossil fuels and natural gas sectors of production, often require boiler, the general common is to transform into a coal-fired furnace gas-fired boiler, to change the high fuel costs of coal on the environment cause serious pollution problems, specific issues unique boiler is not a small project, you need to pay attention to a good close links with each transformation in order to avoid failure of transformation, on boiler should be noted that we have to understand the following description. 1, the original boiler demolition work; boiler before carrying out the original host and auxiliary boilers need to be demolished, concrete demolition work carried out by professional staff, in order to more quickly complete the demolition work with but also to prevent the demolition process in the event of any accident; 2, note that pressure capacity of the boiler; small boiler into the gas by the coal-fired, also changed the original negative and positive pressure combustion burner, the process you need to pay special attention throughout the furnace wall the structure and sealing, the sealing function, it might cause the boiler after the transformation could not withstand the pressure and accidents; 3, furnace renovation precautions; when in many cases will change the gas burner, because the fuel mist of poor or incomplete combustion of the fuel gas remaining in the furnace a little mistake will cause fire or explosion, it is carried out after completion of the transformation for an explosion vent installed in an appropriate position to prevent the explosion, while additional ignition flame protection means after the boiler guarantee safe operation; 4, after the transformation of the test; after the completion of high-quality boiler transformation, but also the need for reuse Sophisticated testing to confirm their safety, commonly used test method is boiler pressure after the transformation of high-pressure test, and finally pass a test meet the standard may be considered completed after the entire transformation boilers. Caution visible through major transformation over the course of gas boilers, boiler reconstruction requires not only technical but also need to meet the relevant standards in order to ensure more successful boiler and can be smoothly carried out using, of course, in the transformation of the former users need to analyze the structure of the entire boiler study, confirming boiler renovation project can be re-introduced in order to avoid unnecessary waste.

Dongying City, Shandong Province in response to low-nitrogen coal-fired changing industrial black oil boiler tos, industrial waste heat recycling and other environmental policies, combined with local conditions, Dali urban and rural areas to promote clean heating projects, and achieved remarkable results. As of mid-October this year, Dongying City clean heating rate of more than 72%.

Recently, Dongying Municipal Urban Management Bureau to the outside world, in order to further promote the urban and rural clean heating, it has already shut down 10 coal-fired boilers environmental non-compliance of a total of 155MW.

After shutting down 10 coal-fired boilers environmental non-compliance, Dongying City high environmental standards were established in a total of four 58MW gas-fired boiler and a total of four 70MW coal-water slurry boiler through a series of energy-saving treatment, flue gas emissions much higher than the index of new environmentally friendly ultra-low emission requirements.

Meanwhile, Dongying City, the original heating effect is also unsatisfactory 4.33 million square meters of heating regions to establish a uniform heating systems, and the use of standards to ensure clean heat source; higher operating costs for the original 2.17 million square meters of heating area heat source replacement process, both to ensure good heating effect but also saves a lot of money.

According to statistics, this year the city of Dongying city plans to add a total area of ​​clean warm 8.1138 million square meters, down to the next new clean heating in rural areas 45000.

Recently, Dongying City issued a "Dongying City 2018-- 2020 coal consumption reduction alternative work" (the "Program"), after the completion of the city's 10 steam tons / hour and small coal-fired boilers zero and start steaming for 35 out of work t / h coal-fired boilers and, as of 2020, out of 35 steam tons / hour and coal-fired boilers.