boiler supplier

coal assembly pipe steam boiler products

Run chemical plant boiler problems that may arise is what chemical plant boiler operation possible problem is? There are two main chemical plant boiler evaporation: evaporation and rated maximum continuous evaporation. When the chemical plant boiler load is higher than the maximum continuous evaporation, it indicates the operating force or overload. The following problems may occur super-load operation: Main results are as follows: (1) due to increased fuel consumption, furnace volume heat load increases, the furnace temperature and furnace flue gas outlet temperature, resulting in the superheater and reheater the superheated steam temperature and wall temperature, and must therefore be strictly monitored and adjusted. Try not to let this time overheating. Coal furnace, furnace volume due to the increased thermal load, increasing the likelihood of slagging. (2) the flow rate of chemical evaporation apparatus system working fluid increases, the flow resistance is increased, it is not conducive to water circulation. Therefore, we should pay particular attention to the monitoring of the water cycle bad area. (3) the pressure differential between the drum and the superheater outlet flow increases as the working fluid and superheater flow resistance increases, so that the pressure of the steam drum and headers increases, the strength of these components must be considered . Space volume load (4) the steam drum, the load increases the evaporation surface, saturated with water vapor would increase, thus affecting the quality of steam. (5) chemical plant boiler safety valve Total displacement designed according to a maximum continuous evaporation. If the chemical plant boiler overload, once the sudden load shedding, the safety valve will not fully open, the steam pressure can not be reduced quickly. At this point, it is necessary to ensure the safety of the boiler by chemical vapor released into the air exhaust valve. (6) With the increase of the amount of air required for combustion and the amount of smoke produced, once sufficient air supply, the air volume is insufficient, the chemical conditions affecting the combustion boiler, increasing the likelihood of slagging; In addition, since the flue gas velocity the increase in fly ash increased the degree of wear of the heating surface. (7) during operation, the exhaust gas temperature rises, the exhaust gas heat loss; shorter residence time in the furnace the fuel, incomplete combustion heat loss of mechanical and chemical incomplete combustion to increase the heat loss, reduce the thermal efficiency of the chemical plant boilers. In summary, the excess chemical plant boiler operation have an adverse impact on the security and economic, should generally not excessive run. If the special emergency must also be strictly limited scope and excess power beyond the time required to force.

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 coal assembly pipe steam boiler products combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 hot water boiler combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 โ„ƒ, 58MW of 998 โ„ƒ. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 โ„ƒ. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

At the end of 2017, China Guodian is located in Jiangxi Province Wanan Hydropower Plant After evaluating the situation, some of the coal assembly pipe steam boiler products used to purchase much-needed daily work. Sales Manager fast boiler combined with the actual situation of the power plant for its recommendation 2 0.5 tons of electrically heated steam boilers.

Some of the causes direct impact on the thermal efficiency of horizontal coal assembly pipe steam boiler products of the country are carrying out a blaze of glory roaring coal to natural gas operations, the choice of horizontal steam boiler, greatly reducing the fine dust contaminated with dust, along with toxic gases such as nitrogen oxides emissions It has also been suppressed. Thermal efficiency is a key measure of horizontal steam boiler, a good start and that is that let you look at some of the causes direct impact on the thermal efficiency of horizontal steam boiler. Through research departments, the heat loss of horizontal steam boiler is very important from two aspects: the combustion air-fuel ratio is not satisfactory and Smoke and heat loss. Smoke and heat loss reduction should be modified in the tail horizontal steam boiler soot waste heat recycling install, or choose would be more leading series condensing boilers. Combustion air-fuel ratio over the substandard Analysis: common horizontal ejector-type steam boiler burner choice, without the formation of air-fuel ratio can be flexibly adjusted. Most of the horizontal steam boiler selected non-automatic strong emission burner, leading to the root causes of unsatisfactory air-fuel ratio has the following areas: air-fuel ratio is not ideal is more important is divided into two kinds of probability: When an excess of oxygen, there will be endless excessive cold air is heat conduction, resulting in increased energy consumption horizontal steam boilers, hot horizontal steam boiler efficiency decreased; when oxygen is not standard, incomplete combustion occurs, generating heat horizontal steam boiler efficiency decreased.

Related Information