boiler supplier

coal fired steam boiler China for plywood industry

Burns Hospital Affiliated Hospital of Shanxi Linfen Linfen Steel is attending a hospital burns burns and other diseases. Hot water boiler is essential hospital equipment heat, hot water output can provide disinfection of medical instruments and ward heating demand. With constantly improving our environmental policy, boiler correspondingly introduced more sophisticated Use. Linfen hospital burns to respond positively to the national environmental policy, decided to introduce an environmentally friendly low nitrogen gas hot water boiler. Taking into account the special circumstances of the hospital, the boiler should also have the use of safe, clean overall characteristics. Based on the above considerations, finalize the Linfen hospital with burns boiler party cooperation fast, fast is provided by one side of a gas condensing pressure hot water boiler (CWNS2.1-95 / 70-Y.Q).

6 tons adjusting a combustion gas coal fired steam boiler china for plywood industry, normal combustion boiler three basic aspects of indicators include a uniform supply of the fuel, reasonable ventilation, adjustment the combustion. 1, to maintain the high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100 ~ 1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. 2, fuel ash to reduce ash content in the combustibles to be below 10%. 3, reducing the temperature of the boiler flue gas exhaust gas temperature should be controlled below 200 ℃. 4, holding furnace negative excess air boiler is 1.2 to 1.4, by adjusting the balance of the blowers to maintain the furnace pressure is -20 ~ -30Pa. 5, the thermal efficiency of the boiler to improve the thermal efficiency of the boiler should be kept above 60%. II. Combustion Adjustment 1, the amount of fuel to air required for combustion and the amount of a reasonable distribution. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. 2, the thickness of the seam and seam thickness configuration grate speed is 80 ~ 120mm grate speed at high, middle and low profile configuration of several commonly used methods:. 9a rapid combustion of thin seam b c thick seam in low combustion. 3 thick seam combustion speed, the segment with the wind blowing principle: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. Normal combustion conditions are: fuel from the coal at the beginning of the fire shutter 300mm, uniform flames, the fire bed formation, at the end of combustion from the end of the grate 300 ~ 500mm. 4. maintain proper furnace temperature to avoid coking. The fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. 6. The residence time of the fuel on the grate in less than 30 minutes.

In a pressurized fluidized bed boiler, the entire fluidized bed combustor is encased inside a large pressure vessel. Burning solid fuels like coal and biomass in a pressurized fluidized bed boiler produces a high-pressure stream of combustion gases. After the combustion gases pass through a hot gas cleanup system, they are fed into a gas turbine to make electricity, and the heat in the hot exhaust gas stream can be recovered to boil water for a steam turbine. Therefore, a pressurized fluidized bed boiler in ZG company has high efficiency and good performance. Each year, ZG invested a lot of money on pressurized fluidized bed combustion technology. Higher techonology and better efficiency is ZG Boiler pursue.

Main contents of boiler energy efficiency test:

1. Boiler thermal efficiency test: a) determination of boiler evaporation; b) boiler excess air coefficient detection; c) exhaust smoke temperature detection; d) fuel combustion efficiency test; e) boiler thermal efficiency test; f) fuel consumption; g) Steam to coal ratio.

2. Boiler new product stereotyped energy efficiency test: Determine whether the boiler thermal performance indicators are consistent with the design and determine the operation mode of the equipment. Such as boiler evaporation, boiler thermal efficiency, combustion efficiency, various heat losses and so on.

3. Boiler operation adjustment test: Determine the most economical operation mode of the boiler and identify defects in the boiler operation. Such as boiler maximum load, boiler minimum load, fuel requirements, economic load, reasonable exhaust gas temperature, optimum wind coal ratio, excess air ratio, secondary air ratio and so on.

4. Comparative test of thermal performance before and after boiler reform: changes in evaporation, effects of combustion, thermal efficiency of boilers, etc.

5, fuel industry analysis, elemental analysis: to judge the quality of oil, gas and other fuels, easy for enterprises to control the quality of fuel into the plant.

6, water quality testing, scale analysis: determine the quality of water, control the boiler water indicators to prevent boiler fouling.