boiler supplier

commercial heavy oil fired water tube boiler Manufacturers

How maintenance of gas commercial fired water tube boiler manufacturers maintenance must be part of the fuel gas-fired boiler? In general, after a three-month run at the beginning boiler maintenance, maintenance of the contents of this means that the furnace kept locally, preventive maintenance boiler run time to the main boiler operators, maintenance personnel, supplemented, DETAILED maintenance contents are as follows: 1, gauge: check and eliminate cocks and condensate pipe joint leaks; checking whether the rotation of the three-way cock gauge pointer returns to zero; check coagulation tube is smooth. 2, water table: Table cocks check the water level; eliminate leakage and air leakage; repair replace the damaged parts. 3, the safety valve: check valve leaks; seal inspection for damage, the exhaust pipe is smooth. 4, piping and valves: Clean up paint and an outer portion; leakage and air leakage inspection of pipes and valves. 5, auxiliary equipment: Check the water supply, circulating water pumps and water treatment equipment. Cleaning the pump inlet filter and oil filter. 6, Thermometer: Check the thermometer should be clearly visible. 7. Automatic control means: checking circuit, a controller, valves, instrumentation and electrical operating system, the line is loose; check the reliability of the ignition process alarm and interlock protection device.

AMD Power were to buy 10 tons of steam and one 4 tons of steam condensing steam commercial fired water tube boiler manufacturers fuel gas from the company for cell processing company production and construction. From the analysis of the demand to the boiler factory, by the company solely responsible for AMD Power fully demonstrated the company's confidence in me, the smooth progress of bilateral cooperation.

Check gas commercial fired water tube boiler manufacturers before the preparation of cease-fire and that the flue slow cooling drum; open all manholes and hand holes in the header of the boiler body; let go of the gas within the boiler drum and water; the boiler combustion chamber, drum , flue ducts thorough cleaning; steam pipeline cleaning and removing rust and scale water; repair or replace a manhole cover; ready safelight, flashlights, test rods, tools and the like. Burner gas is an important part of the boiler, the main control system and combustion system components, the problem lies in easy control cabinet, 1. However, the normal ignition off this failure phenomenon typical cause of several tens of seconds after the self-ignition of the burner flame sensor dirty parts. The flame sensor is a photoresistor when irradiated with light of its own resistance decreases resistance value increases as a state of high impedance low impedance state when the light irradiation. Burner flame sensor controller in accordance with a resistance value to determine whether the process is continued if the combustion stop combustion flame sensor high impedance supply is immediately stopped to prevent the unburned diesel fuel reservoir. Flame sensor probe positioned within the burner duct, since the black smoke, tempering, blowing dust and other reasons that the surface thus losing readily soiling the photosensitive functionality. Check sensor probe, its surface is cleaned with a detergent or alcohol, if necessary. 2. Ignition normal exhaust smoke color but not normal diesel fuel injected into the burner is burning the mixture under stirring, when the appropriate amount of blowing water vapor and CO2 exhaust gas atomization are colorless. When there is insufficient air supply can cause incomplete combustion of diesel soot to form CO and thus give rise to the phenomenon of black smoke exhaust. However, if a strong wind inlet excessive combustion of oil mist may be blown off too late will form white smoke is discharged. Common causes of black smoke exhaust of combustion into the throttle opening is too small, white smoke into the throttle opening is reason to see through the large, two cases should be re-adjusted into the throttle. Exhaust smoke color can be observed while the side damper opening degree until near colorless in exhaust smoke color adjustment. Another reason is that black smoke exhaust poor atomization of diesel, oil mist contained in the larger droplets, can not be sufficiently mixed with the air due to a local incomplete combustion produce soot.

In general, there are many factors that affect the price of the commercial fired water tube boiler manufacturers. ZG boiler 10 tons oil and gas water tube boiler is a very popular boiler in many industries such as food factories, paper mills, hotels, planting greenhouses. In many industries, the use of steam boilers is the equipment that is required for many processes. Heating boilers are also a demanding device. After statistics, the 10 ton boiler can adapt to many environments. The price of 10 tons of oil and gas boilers is a concern of many customers.

Related Information