boiler supplier

factory Dealer price 200 liter steam kettle boilers

3, looking for formal professional

There are many boiler company, scale, formal, professional renovation company does not have much. Boiler is a highly technical operational work, a large scale, qualified and experienced the transformation of the company, in the transformation, can avoid many failures due to technical immaturity caused.

On the hot water factory dealer price 200 liter steam kettle boilers which will have its scale hot water steam boilers in use, may cause problems such as scale, once the scale, then we should be immediately removed, so as not to impact the normal operation of the boiler. However, not a single kind of scale, we must first look at what kind in the end there will be, so as to more targeted and better to clear it out. Torch burning industrial equipment on to explain what kind of hot water boiler scale what its contents are as follows. Hot water boiler scale in general, these are the following: 1 carbonate scale: its main component is calcium carbonate and magnesium, but is mainly calcium carbonate, which is generally white color, which produces parts, mainly in some relatively low temperature site. 2. sulfate scale: its main component is calcium sulfate, is relatively hard and dense, white or yellow color, which appears parts, mainly elevated temperature strength and evaporated in a relatively large evaporation surface. 3. silicate scale: its composition is more complex, silica and the like, which is very hard texture, off-white color is mainly present in the boiler heating surface strongest parts. 4. Mix scale: scale and mixtures of these types is the rust, which has a plurality of colors, and a multi-layered form, which is not fixed portion occurs.

What are the requirements should be equipped with general hot water factory dealer price 200 liter steam kettle boilers circulation pump and two kinds of water supply pump, the boiler is the hot water circulating in the system, it is necessary to use the circulation pump, the hot-water boiler system is to make the circulating pump and fill pump water boiler water loss at the same time be supplemented, you must use the fill pump. First, selection of a hot water boiler circulating pump 1, the flow rate of circulating pump, should be determined that the user heat consumption and pipeline heat loss temperature difference depending on design and other factors. When the bypass pipe mounted between the boiler and the circulating pump outlet pipe inlet pipe, it should be included in the cycle of water flow through the tube Wangpang. 2, not less than circulating pump head of each of the following: ① hot water boiler or heat exchanger inside the pressure drop across the system. ② supply and return water mains pressure drop. ③ pressure drop within the system user. 3, circulating pump operating in parallel, using a characteristic curve should be the same. 4, the number of circulating pumps of heating systems should be based on the size and operation mode determining adjustment, generally not less than two. When any one stops running, the total flow of the remaining water pump should meet the needs of the largest amount of circulating water pump, and reliable measures after a sudden over-temperature boiler pump, boiler water vapor and water hammer should have prevented. Second, the selection of a hot water boiler supply pump in claim 1, the flow of boiler feed water pump, in addition to the normal quantity of feed water should meet the hot water boiler system, due to an accident should meet the increased quantity of feed water, typically 4 to the normal quantity of feed water 5 times. 2, the supply pump head, not less than replenishment point pressure plus 3 × 104 ~ 5 × 104Pa. 3, the supply pump is generally not less than two, wherein a spare. 4, it should be equipped with automatic hot water boiler feed water means and the water supply means provided with manual control of the pump operation or division location fireman.

Oriental Hawaii Holiday Hotel is located in Xiaogan City of Hubei Province in accordance with international five-star hotel standard design, set business rooms, SPA bath, foot care, indoor spa and other facilities in one of the hotel. Hot water factory dealer price 200 liter steam kettle boilers is one of the important facilities normal operation can not be separated. With the pace of Hubei Province in response to the national defense of the blue sky, the use of clean fuels gradually increase the proportion of Oriental Hawaii hotel provides visitors to the more perfect leisure experience a sense of the original wishing more polluted coal-fired boilers to replace clean and green gas-fired boiler. After comparing several vendors boiler industry, a number of R & D results very fast square value in the field of clean fuels, entered into a collaboration with the fast boiler. Fast boiler integrally provided a 1.4MW condensing pressure hot water boiler (CWNSL1.4-95 / 70-Y.Q) according to their actual needs. Put into use, fully meet the needs of Oriental Hawaii Holiday Hotel heating and hot water supply.

Related Information