boiler supplier

fire tube boiler flow chart

Fuel steam fire tube boiler flow chart characteristics analysis of nine large furnace space using fuel steam boiler with a boiler, the steam store more adaptable load capacity and many other advantages, (Gasshow) would like to know more about fuel steam boiler? That take a look at the following bars. The current recommended articles: Gas pipeline installation specification fuel steam boiler nine characteristics: 1, advanced steam boiler automatic controller, Chinese LCD screen, man-machine interface (Gasshow) Users only need to easily set, boiler i.e., according to user requirements start and stop, load adjustment, automatic water supply, such as automatic operation. Boiler fully functional, complete protection, easy to operate, safe, reliable, self-diagnostic function. Boiler operation anomalies automatically interrupt burning, audible alarm once appeared. 2, boiler burner fuel steam boiler is supplied by well-known manufacturers in the world, according to the automatic combustion controller instructions, stop, separate control box has a number of security, safety and stable performance, low maintenance. 3, vertical steam boiler burner set under way, double return configuration, fuel combustion, boiler stable; inserted spoiler smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reduce user cost. 4, the fuel vapor boiler shell type three return all wet back downstream pyrotechnic pipe structure, the combustion flame in the combustion chamber large positive pressure, fully extended, low combustion heat load, high (Gasshow) heat of combustion efficiency, effectively reducing the exhaust gas temperature, energy saving, economical use. Waveform threaded pipe and furnace structure, i.e. increase the strength of the heat absorption of the boiler, but also to meet the needs of thermal expansion of the heating surface, scientific and rational, and durable. 5, in strict accordance with the present boiler "Steam Boiler Safety Supervision", JB / T10094-2002 "industrial boilers general technical conditions", JB / T1619-2002 "boiler manufacturing technology conditions potshell" requirements, design, manufacture, monitoring inspection to ensure good quality of boilers, achieve low energy consumption, high thermal efficiency, stable pressure, gas and quantity, economic use. 6, the fuel steam boiler furnace space, storage of steam and more adaptable load capacity. Rational design of steam separator apparatus built to meet user requirements need to use higher quality steam. Furnace open manhole, head holes, hand holes, to facilitate the internal furnace to clean up, make repairs, maintenance is very convenient. Gasshow Information: Gasshow provide gas technology, supply and demand information we needed. More timely, accurate and comprehensive. Gasshow information Everyone is invited to contribute. Gasshow URL: www.gasshow.com7, boiler safety interlock with multi-level protection: protection pressure switch (higher than the set auto stop and pressure), the low water level protection (boiler water level is below the warning level present in vivo, automatic cutting off power and alarm), a safety valve to protect (the boiler pressure exceeds the pressure of work, discouraged automatic blood pressure), ensure that the boiler in a variety of conditions foolproof, secure home. 8, the appearance of the fuel steam boiler mechanical and electrical integration of organic combination of sophisticated new, compact, occupy less space, easy to transport and install. 9, using the new material and the thermal insulation quality white color plate package, lighter in weight, good insulation properties, beautiful, not rust.

The emergency shutdown and shutdown procedures Henan fast fire tube boiler flow chart's small series with you about the procedure and the shutdown of the emergency shutdown. 1 steam boiler load regulation is to regulate water temperature, when the weather changes, fireman according to outdoor temperature changes, according to "a network for the return water temperature hot water boilers shall have the following situations arises A. emergency shutdown due to circulating water pump failure or power outage suddenly stop running, stop the flow of water in the system, resulting in over-temperature vaporization of the boiler, after the exhaust valve, pressure gauge is still rising. B. heating system due to frost or other reasons, do not send out hot water, boiler water over-temperature vaporization, causing serious water hammer. C. Analyzing indeed boiler water, over-temperature caused by vaporization of water must not at this time into the boiler. D. supply pump all damage or failure of the constant pressure device. A short time can not be repaired. E. circulating pump all the damage can not be repaired within a short time. F. external piping serious leak, after replenishment can not maintain the system pressure, causing system and boiler vaporization. G. boiler pressure parts damaged, thereby endangering the safety of operating personnel. H. combustion equipment badly damaged, furnace or boiler wall came down red-hot steel and so on, a serious threat to the safe operation of the boiler. Emergency shutdown procedure:. A fireman when an emergency shutdown, should calm calm, judicious, to distinguish between cases, steady, accurate, fast processing, the tension must not panic, because an error of judgment and put an end to the expansion of the accident. B. supply of the fuel, the air blowing is stopped, the wind reduction, reducing the temperature of boiler water. C. accelerate the rotational speed of the grate, a boiler furnace fired quickly discharged, so that the fire goes out, but the non-water poured into the furnace flame. D. After extinguishing the fire, the damper is opened, natural ventilation. E. If the vaporization has occurred, should be immediately shut down for the return valve, the boiler and the system has occurred vaporization of isolation. With the exhaust valve, open the bleed valve and boiler water valve, the cold water inlet side exhaust side reduction furnace, boiler pressure below the inner boiler allowable value. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

Electric fire tube boiler flow chart protection measures must be taken! Look at your electric boiler has none of these measures: In recent years, more and more users start using large electric boiler heating equipment, surface phenomenon, people began to realize environmental protection, energy saving importance. Fast boiler electric boiler production precisely because there is no combustion chamber and chimney, with a clean environment, no pollution, no noise, automatic, user groups in the widely popular.

Jinzhou construction and installation company needs an electric heating hot water fire tube boiler flow chart house construction, after screening and comparison of various brand boiler industry, our excellent results in the cleaning of the boiler industry has been attracted to each other, in mid-2016, the Jinzhou construction and installation the company I signed with an electric heating pressure hot water boiler.

Related Information