fuel oil 16 tons industrial hot water boilers

Gas-fired steam boiler equipment maintenance equipment maintenance points 1: 1, or twice a day to clean up slag. 2, washed once or twice a heater dust (ash door with the appliance design) weekly. 3, once or twice a month, or butter oil feeding helical gears and bearings induced draft fan. 4, a monthly injection of butter or oil to the fan motor bearings once or twice. 5, a boiler must be 2-4 times the annual emissions (emissions must promptly after filling water). 6, poor water quality, in use. 2. Before, must soften water. Gas fuel 16 tons industrial hot water boilers with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Daily inspection equipment: 1, the fan regularly checks whether there is a feed screw loosening device, whether there is abnormal noise. 2, regular inspection trip tank float valve is normal replenishment, water pressure is normal. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. 3, if equipped with a pump, replace circulation pump on a regular basis, and check whether the pump is working properly. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 4, regular inspection equipment grounding cable is connected correctly. 5, to ensure the normal supply of fuel in the hopper, so as to avoid non-fuel flameout downtime. 6, it should be observed regularly combustion of the fuel in the combustion chamber. Incomplete combustion of fuel, smoke or large block to form sulfur, the sulfur should be promptly removed block and the governor to adjust the feed flow rate ratio of the fan, to achieve the desired combustion.

Xiamen Rui Yi Hotel is available straight left Gulangyu the most beautiful views of the BRIC countries delegations designated top hotels, the best location in the heart of Xiamen, modern trends and classic style pavilions. The hotel features well-appointed room service, fashion and superior restaurant, bar, meeting rooms and a gym, swimming pool and other recreational facilities, people feel contented and comfortable. Projects and programs as Xiamen Rui Yi Hotel Xiamen City landmark hotel building, attaches great importance to environmental protection philosophy, which party fast boiler manufacturing philosophy coincide. In late 2016, the two sides signed an electric steam boilers for hotel supplies disinfection work, since the electric steam boiler, any security incidents never happened, Rui Yi Hotel ensure normal operation.

How to reduce the scale of known gas steam boiler steam boiler heating surface of the machine is the primary supply of high quality steam. Past, steam appeared to mankind brought great changes. The emergence of the steam era of human civilization introduced the modern era. Now there steam boiler once again that human potential is unlimited, it appears there are a lot of people to help. Steam boilers plays an important effect on people's day in. It's like bathing, eating, and other industries. It is said that the local demand for steam boiler steam demand. Steam boiler steam supply is the primary tool. Industrial production in the steam boiler to supply steam for the people, with the production of human power supply, making it easier to produce in the production. In the days of steam boiler supplying steam can help people make food, why we can take a bath with a steam boiler in the cold winter. These are to help supply the steam boiler. Steam boiler steam can easily supply better for us to make our life easier and more convenient. About steam boiler, we should be careful when they use their maintenance work, so that it can help us longer. Steam boiler in direct contact with the heat exchanger, the high heat recovery, contaminants in the flue gas are also removed, but acidic water quality, which is not convenient for the fuel 16 tons industrial hot water boilers. The so-called direct heat exchangers is that we often call for means for recovering heat from the flue gas condensation. Now, more and more people choose to use the steam boiler, the share of the market share continues to add. Flue gas discharged from the steam boiler containing a lot of water vapor, is condensed through the release of a lot of the latent heat of vaporization, which is more than a coal-fired boiler. a lot of. This boiler better selection of direct heat exchanger. Industrial production is the primary driving force of the world expanded, is very important for the expansion of the world. Therefore, we need to use steam boiler supplying steam better for us, because of our human expansion needs of these sophisticated machines help. No machine age is primitive society. When humans learn to use tools, it marked the beginning of civilization has already begun. Steam boiler is a tool we humans can do to help expand. No matter how preparedness, gas steam boiler, after working long hours, more or less will have some scale. Gas steam boiler is in operation, the furnace will be a series of chemical and physical reactions, the application process, will form a strong and fine scale on the heating surface, which would lead to a direct heat exchange efficiency of the boiler decreases; and by the effects of corrosion under the scale, will lead to reduced water wall furnace heat absorption gas steam boiler, then dropped thermal efficiency, waste of capital investment. The necessity of finishing scale there is little that is durable stable job and let the boiler down. As long as the thermal conductivity of the scale of one percent of the steel, once the heating surface fouling, so that the heat transfer will be impeded, in order to maintain the boiler must be output in the use of the process, it is necessary to progress the fire-side temperature. Process outlet temperature of the furnace gas steam boiler making added, so it will make the loss of added gas steam boiler, reducing the heat transfer effect that it would be useful after fouling equipment in the water wall, so it is very likely Add water wall tube wall temperature can cause lead to burst pipes water wall. Cleaning the boiler becomes particularly important. Performing the cleaning process, you can use efficient, environmentally friendly and non-corrosive cleaning agent, so that the device will reveal the original metallic tube, down to fouling. Secondly, in the incinerated gas steam boiler, furnace needs careful investigation smoke temperature and the temperature of the main steam changes; when the main steam pressure in the rising condition, if the boiler burning smoke temperature rise speed or does not rise significantly Pianman, immediately Check the oil gun fire situation.

Maintenance of the boiler and burner maintenance 1, boiler maintenance and deactivation of backup boiler, should take anti-corrosion measures. 1) maintenance Calorimetry: maintaining the furnace pressure 0.05 ~ 0.09MPa, the water temperature of about 100 deg.] C, to prevent air entering the boiler, this method is suitable within a boiler shutdown week. 2) Wet maintenance: After disabling the boiler, put the water came out, the interior completely remove the dirt and cleaned, refilled been handled well demineralized water, softened water filled boiler. Then adding alkali to the boiler, when added with sodium hydroxide aqueous 5 kg per ton to 6 kg, per ton of sodium carbonate was added if the water 18 kg to 20 kg per ton of water when trisodium phosphate is added 10 kg to 12 kg, maintaining the PH value above 10. The furnace was then heated to 100 deg.] C water, the safety valve is opened, air is discharged in the furnace, and then closed. During maintenance should always check and found that leak that is to be cleared. When the boiler is enabled, it should be drained alkaline solution, and rinse with water, especially when the plot scale boiler must deactivate more clean, because the scale can be soaked in lye and fall off, clog pipes. The method is suitable for longer-term disabled boiler. 2, the burner maintenance: 1) cleaning and maintenance of the burner: Open the combustion head, with a cleaning wipe member or combustion gas, a flame detector wipe with a clean soft cloth, carefully clean the duct and the fan wheel. 2) maintenance of the oil (gas) passage system: Remove fuel (gas) pipeline, cleaning fuel (gas) each filter and nozzle, the drain valve is opened daily oil tank, with exclusion of moisture and impurities in the waste oil. 3) maintenance circuitry: Check whether each wiring is connected firmly assembly is intact and the like.

Related Information