Fuel gas-fired boiler fuel gas-fired boiler product presentation is different from coal-fired boilers, which requires the use of a burner fuel is injected into the boiler furnace using a combustion chamber without the use of fire grate facilities. Because not produce fuel ash after burning fuel gas-fired boiler, fuel gas-fired boiler so without slagging facilities. Oil injected into the furnace, if the gas and air mixture within a certain range, or turned off, it is easy to explode. Therefore, fuel gas-fired boiler combustion required to adopt automation and control systems. Fuel gas boiler compact, small boiler and ventilation, water supply, control and auxiliary equipment are arranged on a distribution box, it may also be assembled and medium-sized factory. Fuel gas-fired boiler safety valve installation points introduce fuel gas-fired boiler safety valve needs to be installed in the correct installation steps, in order to avoid mistakes, resulting in what needs to pay attention to danger, fuel gas-fired boiler safety valve installed it? Here, I introduce: 1 fuel gas boiler safety valve should prevent the lever means and movement of the self-weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly . 2. Rated to 0.5t h evaporation boiler fuel gas /, at least two safety valves installed; Rated evaporation 0.5t h or less fuel gas boiler /, mounted on at least a safety valve. The separable exit of the economizer, steam superheater outlet of the safety valve must be installed. 3. Fuel gas-fired boiler safety valve to the boiler tubes, cross-sectional area should not be less than the import safety valve cross-sectional area. If several valves installed together with a short tube directly connected to the drum, short tube passage area not less than 1.25 times the area of ​​all the exhaust valve. 4. Fuel gas boiler safety valve should be installed vertically in the boiler drum, header high position. Between the valve and the drum or header, not equipped with access to the steam outlet pipe and the valve. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20mm. 6. Fuel gas-fired boiler safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust. Safety valve exhaust pipe at the bottom should be fitted to the safe location of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve.

Recently, the Ministry of Environmental Protection by the volatility of the newly revised "Boiler Air Pollutants Emission Standards" released in July this year, the implementation of this standard is known as by far the most stringent air pollution emission standards for boilers, boiler caused by the manufacturing sector.

Compared with the existing standards, new standards not only revised the traditional particulate matter and sulfur dioxide emission limits, for the first time proposed emission control standards for nitrogen oxides and mercury, Forced boiler manufacturers have to upgrade technology, from the source control boiler discharge atmospheric pollutants.

One side is desulphurization and denitrification entered the final stage, while the new emission standards of air pollutants are being introduced amendments to the boiler. Such as pollutant emissions from large wide range of small capacity monomer emission coal-fired boilers and other issues close to the ground long standing will once again be enlarged, comprehensive improvement of coal-fired boilers will undoubtedly become the next focus of urban air pollution control. Analysts believe that the implementation of the new standard direct-driven investment in environmental protection will reach 370 billion yuan to 4500 yuan, while the boiler manufacturing industry is facing exams has also led to the relevant environmental protection equipment market to break out again.

By the end of 2011, our country in the boiler 620,300 units, of which 09,700 units utility boilers, industrial boilers 610 600 units, with a total capacity of about 3,515,900 kilowatts. In 2012, industrial boilers reached 62.4 million units, about 98% of the total number of boilers.

In industrial boilers, coal-fired boiler is more than 80%, the annual consumption of 490 million tons of standard coal, the average efficiency of 65% to 70%, emissions remain high.

In 2012, coal-fired industrial boilers cumulative emissions of dust 4.1 million tons, 5.7 million tons of sulfur dioxide, nitrogen oxides 2.0 million tons respectively, accounting for 32% of total national emissions, 26% and 15%, a major cause of fog and haze one of the reasons.

For this reason, in the 2013 set off a nationwide clean energy alternative coal-fired boiler boiler, more than one place Shandong, Shanxi and other relevant measures have been introduced on clean energy alternative to coal-fired boiler work. "The introduction of the implementation of the most stringent standards, will set off a coal-fired boiler in the second round.

Four existing small and medium sized coal-fired boilers in China. One pollutant emissions from large, wide surface. Second, small-cell capacity, the average capacity of 8 tons / hour, the number of 10 tons / hour of small coal-fired boilers is 42 million units, accounting for two-thirds of the total. Third, emissions close to the ground, a great impact on quality. Fourth, boiler technology, main and auxiliary mismatch, poor health. In addition, most small boiler lack of dust removal, desulfurization and denitrification equipment, led to the current sulfur dioxide and dust emissions from boilers widespread non-compliance.

From the present point of view, domestic clean energy technology matures, the implementation of new emission standards for technology development has brought very good driving force for the future, who can stable up to standard technical requirements of the country, will have a presence in the market value Otherwise it can be eliminated.

Check the work before the start fuel gas-fired boiler in order to protect the safe operation of the gas boiler, improve operational efficiency boiler, make sure to check the work before the boiler starts, every detail can not be ignored. 1, check the safety accessories, thermal instrumentation, electrical instrument should be intact; 2, check the connections, whether the water leakage and the furnace body line; 3, check the waste line, the water line, return line should be smooth; 4 , should check the line voltage is 380V, the fluctuation should be within ± 5%; 5, oil-fired boiler and a filter pump check whether normal oil, gas boiler check the gas pressure is normal, not too high or too low, the oil supply opening valves; 6, check whether the pump Sheung Shui, or opening the purge valve, until the Sheung Shui so far. Water Supply System opens each valve (including the water pump and water valve before and after the boiler); 7, check level gauge, the water level should be in the normal position, to prevent false water level, if the water can be manually Sheung; 8, check the pressure conduit the valve must be opened, the wind deflector must all flue opening; 9, each knob inspection control cabinet are in their normal position; 10, a check valve should be full auto steam boiler in a closed state, the hot water boiler circulating pump valves should be closed state; 11, check water softening equipment is operating correctly, create a variety of indicators of soft water meets national standards. Carefully do the above inspection, the basic conditions for the fuel gas boiler safe and economic operation.

The control device talk boiler automation instruments in use in boilers, their controls automation instrument is extremely important, we are concerned that today. Evaporation of 4t / h and 4t / h boiler or less. Detecting water gauge, vapor pressure gauges, water pressure gauge, water thermometer, thermometer smoke, steam flow calculation. Oil temperature, oil pressure, oil level indication, computing fuel, furnace exit gas temperature indication. Boiler flue gas oxygen content should have, furnace pressure, economizer import and export water temperature indication. Or continuously adjusting the position feedwater automatic control, automatic adjustment of a combustion boiler burning heavy oil should be automatically adjusted, should there boiler pressure adjusted automatically. Alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. Auxiliary electrical control box, the boiler should be equipped with explosion-proof electrical control equipment. Programmable and others. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.