boiler supplier

gas steam boiler Dealer price 1000 kg indonesia

Process safety valve check valve gas steam boiler dealer price 1000 kg indonesia is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

Gas-fired steam boiler dealer price 1000 kg indonesia which in modern industrial production, although the boiler very prominent role played by the choice of cleaning agent, but it is also very easy to scale boiler is subject to corrosion or damage. Gas boiler steam heater in such a situation therefore requires timely associated boiler equipment for cleaning, and performance of the practical utility of the most prominent non-gas-steam cleaners which is none other than this. Where a new gas heating system to replace the steam pipe cleaning agent must be used to eliminate the inner wall of debris so as not to affect gas-steam heat transfer efficiency and service life. It should be carefully checked, in use, to prevent water, acid, alkali and leakage into the low boilers using the system, and to install the filtration device, to prevent mechanical debris into the system to ensure the purity of the oil. A gas-steam with hot brands and process requirements, the correct selection of various grades of high-temperature gas-steam, and strictly abide by the provisions of the "organic heat carrier furnace Safety Technology Supervision" in the proper use of gas steam. Gas steam boiler at a high temperature gas for gas steam, gas, fuel furnace as a carrier, electric heating reactor and other heating devices, shall have the expansion tank and the oil sump and other security components and temperature control instruments and other facilities, to ensure safe operation. Purpose cleaners gas steam boiler is effectively rapid clearance gas steam boiler and the heat exchanger internal conduit accumulated soot and grease. Then we also have requirements on the cleaning agent, must not harm our metal heat transfer surface, requiring no residue, is completely dissolved, it must be easy to operate and requires only the use of the process in accordance with the needs of ordinary people to operate. Requires us on the gas boiler steam oven cleaners are: low energy environment, Wudu tasteless, non-flammable, irritation, can be directly discharged after cleaning.

Environmental Protection measures of Environmental Protection BoilerEnergy-saving and high-efficiency atmospheric pressure environmental protection boiler can convert black smoke into gas combustion and save coal consumption. The atmospheric pressure environmental protection boiler has double-layer grate and two combustors. If the coal in the upper combustion chamber does not burn well, it can continue to burn in the lower combustor. At the same time, the primary air, secondary air, fuel can give enough oxygen to fully burn. According to the comparison of users' field use, it can save about 30% and 50% compared with the similar big bituminous coal boiler and briquette boiler, etc. The environmental protection standard atmospheric pressure environmental protection boiler can burn all kinds of bituminous coal, and can turn the black smoke into the gas combustion rapidly, the smoke pipe will not emit black smoke, purify the fine dust and the oxygen Sulfur, after monitoring, all indicators meet the national environmental standards. The steel plate of the atmospheric pressure boiler of reliable quality is made of the national standard steel plate, the material is Q235A, Q235B, the international seamless steel pipe, the material is 20, GB3087, GB8163, the production material and the manufacture craft are carried out strictly according to the national standard. After testing, each index also reached the national standard. The operation safety atmospheric pressure environmental protection boiler structure is very compact, the occupation area is also small, the upper temperature is fast, is no pressure operation, safe and reliable. Environmental protection pressure steam boiler dealer price 1000 kg indonesia equipped with a number of safety protection devices, exceeding the pressure, safety valve automatically opened Exhaust steam to ensure safe operation.

After the meeting, accompanied by dealers to observe the company's leadership in the clean boiler laboratory, set comprehensive performance test platform (energy efficiency testing), the burner test platform, systematic energy saving technology and demonstrate real boiler room, Transfer Intensification testing center, centralized control system and other functions, the maximum test capacity of 40t / h, the maximum installed capacity of 40t / h, is to demonstrate, on a test basis technical research products, set in a comprehensive testing center.

Related Information