boiler supplier

giz rice per boiler stove project carlos miro

What industrial giz rice per boiler stove project carlos miro rated output yes? What industrial boiler rated output yes? Boiler rated output power refers to the boiler in the established parameters (pressure and temperature) and the premise of ensuring maximum efficiency at a certain time continuous output. For steam boiler, collectively referred to as the nominal energy of vaporization force, tonnes / hr; for hot water boiler, collectively referred to as rated thermal energy generation. The relationship between the amount of evaporation and heat production: Q = D (iq-igs) 1000 kJ / h where: D ---- evaporation boiler, t / hr ---- IQ steam enthalpy, kJ / kg igs ---- boiler feed water enthalpy, kJ / kg for hot water boiler: QG (IRS-IRS) 1000 kJ / h medium: g- hot water boiler circulating water, tons / hour boiler water irs --- enthalpy, kJ / kg irs --- boiler feed water enthalpy, kJ / kg Note: 1kcal (Kcal) = 4.1868kj (kj)

Second, the system is complete, safe and reliable giz rice per boiler stove project carlos miro module using the direct-fired air combustion, high security. If a conventional single boiler purge is not complete, the residual gas explosion occurs, it can cause a serious explosion. And similar gas water heaters and boilers for home use module, sufficiently mixed gas ignition combustion. Even if the gas leaks, the boiler can quickly exhaust the excess gas, safe and reliable.

Oil-fired giz rice per boiler stove project carlos miro maintenance method "two" First, the maintenance of the body of the boiler heating surface: oil-fired boiler heating surface of the body without long-term maintenance methods: dry and wet two kinds. Shutdown more than one month should be maintained using a dry method, the following can be wet shutdown heart month regimen. ① dry maintenance method: oil-fired boiler shutdown put a pot of water to the interior completely remove the dirt, rinse. Dried in the furnace with Weihuo (be careful not to use the fire), then 10-30 mm lime block installed sub-plate, placed in the drum, without contacting the metal with lime, quicklime weight to drum 8kg per cubic meter volume is calculated, and then all manholes, hand holes, pipe valve closed, checked every three months, such as powdered lime broken into, i.e. to be replaced should be re-run the boiler fuel and the disc removed quicklime . ② Wet regimen: post-fuel boiler shutdown until the furnace water cooled to below 70 ℃ furnace water exhausted, the internal completely remove the dirt, rinse, all manholes, hand holes, pipe valves closed tight, and with a blind plate and the operation of the oil-fired boiler completely isolated. Then re-injecting the treated water softener to a minimum safe level of fuel boiler, and then the alkaline solution will be injected into the prepared oil-fired boiler, which ingredients are: sodium hydroxide (caustic soda) per ton of boiler water 8-10kg, if the choice of carbonate sodium (soda ash), the boiler water per ton of 20kg, or disodium phosphate, boiler water per ton of 20kg. After all of the alkaline solution is added, and then injected into the soft water boiler, up until the water out from the boiler at the top, close to the valve, so that the boiler noted mixed alkaline solution. The maintenance period Microflame oven regularly, periodically circulating water, the concentration of the alkaline solution throughout the same. Every five tests also take a basic solution, such as alkalinity less than 5-12mmol / 1 solution should be applied. Cold climates maintenance of law can not be wet, so as not to damage the boiler furnace water was frozen. Second, maintenance of burners: 1, regular cleaning oil filter. 2, to maintain a sense of photoelectric eyes clean. 3, should be at periodic intervals drainage discharge water accumulated in the bottom of the tank and dirt. 4, at regular intervals, cleaning the interior of the burner. 5, the temperature of the vicinity of the burner is not too high, otherwise it will affect the normal operation or damage the combustor components, in particular damage to the control box. 6, near the burner should be kept clean, can not be placed inflammable debris. 7, some components of the voltage instability will cause damage to the burner. 8, to avoid the burners are splashed water.

Fangkuai Boiler is a clean-up giz rice per boiler stove project carlos miro equipment based on various excellent scientific and technological advancements, focusing on product development, manufacturing, and manufacturing that are more efficient, environmentally friendly, and energy saving, and meet the basic national conditions of environmental protection in China. In order to promote the rapid development of the heating furnace manufacturing industry, people-oriented, consider the specific requirements of customers in the manufacturing industry for heating furnaces in various industries.

Related Information