boiler supplier

good quality industrial oil gas fired steam boiler

Domestic and foreign customers have different preferences for boilers. The local textile factory in Bangladesh purchased one ton of WNS-type gas good quality industrial oil fired steam boiler and one ton of WNS-type gas-fired steam boiler in our company. This is a highly efficient and environmentally-friendly boiler produced by CBM. Oil and gas boilers are very popular in the foreign textile mill. The oil and gas boilers produced by CBM have high automation, simple operation and excellent environmental performance.

Important preconditions on the boiler flue gas dust removal and desulfurization process design engineering boiler flue gas dust removal and desulfurization project is constantly improving our air quality and reducing acid rain PH value. This article will focus on an overview of the relevant boiler flue gas dust removal and desulfurization project elaboration, analysis related to boiler flue gas dust removal and desulfurization process design engineering, to provide reference for China to improve environmental standards. Overview of related dust and sulfur dioxide in the flue gas dust removal and desulfurization project 1 boiler is the main material damage caused by acid rain and the atmosphere, and it is a form of sulfur dioxide is not a harmful gas has a color and pungent, severe cases can damage the atmosphere structure, resulting in environmental change. Not only that, people living with the process of the production process will produce some harmful dust and sulfur dioxide gas, once the proportion of air in these components is too high it will endanger people's health. But also pose a serious hazard to respect people's productive activities, industrial production, construction and so on. Boiler is an energy conversion device, the input energy to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output have a certain outward heat, hot water or organic heat . Boiler is one of the main tools of our country's major industrial production, which will use special means to go after some of the energy input material must be converted into energy, in order to adapt to the development industry. But in the course of the boiler will emit harmful substances, although it will increase the efficiency of economic and industrial development in a way, but also bring a certain degree of damage to the environment, severe cases can endanger human safety. Current coal resources and consumption of oil resources gradually increased, resulting in dust emissions and sulfuric acid type gas also increases. So our national government to protect the environment but also introduced the corresponding countermeasures, continuous improvement boiler flue gas dust removal and desulfurization process design engineering methods to improve its environmental efficiency. Flue Gas Desulfurization relevant principles of the boiler 2 into the operating principle of this embodiment 2.1 magnesia mainly refers to the use of a slurry containing MgO as a desulfurizing agent in the wash, MgO is converted to magnesium sulfite (MgSO3) and magnesium sulfate (MgSO4), the sulfur is then removed from the solution. This approach boiler dust desulfurization more mature and has been widely used in Japan and Taiwan and other regions in mainland China also has many factories, dust removal and desulphurization work in this way. Moreover, this method of dust removal and desulfurization efficiency above 90%, help protect the environment, improve the current air quality. Also in the case where the like, the amount of magnesium oxide with calcium carbonate Desulfurization only two fifths, this method shows a high utilization of raw materials, and the effect is more obvious. Currently stored amount of magnesium oxide in our country up to 80 billion tons, ranking first in the world in mining technology is also more skilled, and therefore has a considerable edge for our country. 2.2 works swirl plate absorber tower for flue gas desulphurization dust from the boiler is first enters the venturi tube, for spraying a primary dust desulfurization treatment, and then a flow rate of 15 ~ 22m / s is tangentially into the swirl plate column cylinder, firstly by the action of centrifugal force, thrown large particles in the flue gas to the tower wall, and a top-down flow of the absorbing liquid trap. This method enables the boiler flue dust separated from the gas, and to achieve the object of dust removal and desulfurization. 3 boiler flue gas dedusting flue gas desulfurization process design inside the boiler through the heat exchanger after the dust removal device into efficient desulfurization device or directly into efficient desulfurization and dust removal device, and then use the exhaust chimney draft fan. In the dust removing device which will produce gray water tank into the lime, a process using sodium lye bath kinds sodium lye, then became lime mud. If there is still the use of multi-level gray water and sludge pump liquid precipitation treatment, after diluting the high water level of the pool can be completed. Therefore, in the boiler flue gas dust removal and desulfurization process engineering design process to rational design exhaust system, flue gas purification systems, precipitation systems, inspection systems, power systems, and infrastructure-related aspects. And actively improve the quality and level design to ensure that the results of the boiler flue gas dust removal and desulfurization national environmental standards in line with the relevant departments to develop. In the process design process should also consider the cost of construction of the whole project, detailed estimates of its economic benefits and social benefits. In the course of implementation should strengthen supervision and management, to improve the quality of the environment and efforts. 4 Conclusion With the improvement of scientific and technological level of China's industrial development speed greatly accelerated. But in the process of industrial development often will use some of the energy resources, such as coal resources, oil resources and other aspects of chemical materials, use of these resources in the process will produce some waste is not conducive to environmental sustainability. Therefore, the relevant enterprises and departments should actively improve the quality of the boiler flue gas dust removal and desulfurization, improve the rationality of engineering process design, lay the foundation for improving the economic and social benefits. This requires the joint efforts of government departments and enterprises, the only way our country's socialist market economy to be able to achieve sustainable development goals, to be able to improve the economic benefits of the greatest degree.

Dry: six gas-fired boiler safety procedures (hot water + steam) stage, the purchase of gas-fired boiler more and more users, in many industries, such as oil exploration, hospital disinfection, chemical production, wine feed, and so on. But many users initial contact with a gas boiler told us how to get started quickly boiler operation is not clear. First, all personnel must be familiar with the operation of the boiler boiler performance and safety knowledge, certificates; this non-job employees Never operate. Duty personnel should strictly follow the regulations, do a good job operating records and shift recording, the security situation should shift equipment and run tests, carried out. When the shift to check the boiler is intact. Second, purchasing, installing, or before the initial operation of the boiler, the boiler and safety accessories must conduct a comprehensive inspection, inspection and determined within the validity period to start. Third, Kai furnace ready to check the gas pressure is within the normal range of values, not too high or too low; check whether normal pump Sheung Shui, if unusual you need to open the purge valve until the Sheung Shui so far. Open the door of each section Water Supply System (including Sheung Shui before and after the festival gates pumps and boilers); check the water level, the water level should be in the normal position, the water level gauge, a water color need to plug in the open position, to prevent false water level, if missing water can be manually Sheung; check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob inspection control cabinet are in their normal position; good quality industrial oil fired steam boiler check valve is in the normally closed state, heat water boiler circulating pump outlet valve should be turned off; check water softening equipment is operating correctly, soft indicators of compliance with national standards. Fourth, Kai furnace run time 1, steam boilers Open the power to start the burner; check manholes, hand holes around the flange and valve leaks will be tightened, if there is still leakage after tightening occurs, you need to immediately stop maintenance furnace; l when the air pressure 0.05 ~ 0.1MPa, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; when the pressure was raised to 0.1 ~ 0.15MPa, rinsed trap gauge; pressure was raised to 0.3 MPa, the "fire load / small fire" knob to "fire" to strengthen the combustion; 2/3 when the air pressure was raised to the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; out when the drain valve when steam is completely close it; after all drain valve closed, slowly open the main valve to open, and then half a turn; "burner control" knob to "Auto"; level adjustment: adjusting the water level (according to the load manually when to start and stop the pump), low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; steam pressure adjustment: adjusting the combustion load in accordance with (manual adjustment fire / small fire) determines combustion conditions The flame color, smoke color determination condition atomisation air quantity and exhaust gas temperature observed concentration chimney, the best change in the combustion temperature to be adjusted according to the combustion. 2, start the circulation pump hot water boiler; startup burner; 15 minutes after start, "" fire load / small fire "spin-bit color button to" fire ";." Burner control "knob to" Auto "five, normal stop 1 furnace, hot water boilers' fire load / small fire "knob to" small fire "; off the burner; close the fuel supply valve; closing dampers; boiler after the temperature dropped to 50 ℃, the pump outlet valve closing cycle ; .2 circulation pump is stopped, the position of the steam boiler "fire load / small fire"; Close combustor; steam pressure drop when the sewage to 0.05-0.1MPA; closing the main steam valve; manual replenishment to the higher level; Close valve; Close supply valve combustion; closed dampers; six off the main power, an emergency shutdown, the steam boiler main steam valve closed; off the main power; 2, boiler water boiler inlet and outlet valve closed; opening the emergency valve and the emergency discharge replenishment valve; off the main power switch; notification superiors.

AMD Power were to buy 10 tons of steam and one 4 tons of steam condensing good quality industrial oil fired steam boiler fuel gas from the company for cell processing company production and construction. From the analysis of the demand to the boiler factory, by the company solely responsible for AMD Power fully demonstrated the company's confidence in me, the smooth progress of bilateral cooperation.

Related Information