boiler supplier

hot water output solid fuel boilers

In fact, the heat generated by the combustion of fuel into high calorific value and net calorific value, high calorific value is the direct thermal efficiency of the hot water output solid fuel boilers we see; but calorific value can not be ignored, if used properly, the two together, the thermal efficiency of the boiler on there may be more than 100% to 108% a.

Blue Sky Battle horn started, our country constantly walking on the green road. Reduce atmospheric emissions of nitrogen oxides, improve air quality, but also the people a blue sky, the industry has invested in the construction of environmental protection go, Guizhou Baiyun Quan Lake Hotel is no exception. As we all know, fast hot water output solid fuel boilers R & D in the field of clean fuel boiler never stopped, through market research and screening, Guizhou Baiyun Quan Lake Hotel in October 2017 signed a low-nitrogen Thalia T5 series vacuum hot water and fast boiler boiler for hot water supply and heating the hotel.

Second, a low nitrogen condensing pressure hot water hot water output solid fuel boilers performance characteristics

1, high-quality materials

Safety valve manual valve oil-fired hot water output solid fuel boilers emission test is necessary to prevent security annex oil-fired boiler overpressure operation when the boiler pressure reaches the pressure relief valve jump start, jump start automatically relieve pressure. If the safety valve does not operate long-term, there is likely to stick to rust inside the valve structure, the valve can not be under pressure to adjust the automatic jump start, will cause the boiler overpressure operation, or even an explosion hazard boiler. In order to prevent the relief valve and valve seat stick, according to "Boiler Code" provides manual drain valve should be periodically tested. Oil-fired boiler Procedure: (1) in the boiler operation, when the state of the pressure pot 75% or more boilers operating pressure is reached, check valve use, to confirm the absence of abnormality, emissions test done manually; (2) valve lifting handle or the weight slowly, this time should jump start exhaust valve; (3) after 3-5 seconds, the weight or the handle down, the safety valve should be closed; (4) If the valve is not closed Yan, should be repeated by lifting the handle hammer until closed. If the valve is still closed tightly, the need for shutdown valve repair or replacement: stop the pump, the pump to stop, stop the fan off the main power, boiler exhaust valve opening, closing sub-cylinder inlet valves, valve disassembly, after repair or replacement, installation of safety valve, and then open the safety valve check if no abnormal, turn off the safety valve; (5) if jump start, a safety valve spool may be stuck foreign matter or embroidered dead, need for safety shutdown a valve for repair or replacement. Safety valve should be manually emission test points to note: (1) the pressure pot manual drain should be at least 75% of the state working pressure, prevent manual drain valve does not jump start at low pressure. (2) If there are two or more boiler safety valve, the discharge should be done in the first row of the high value of the low back valve. (3) for lifting and a manual valve handle should Qingtai light or weight, can not be used for lifting and Meng Jin. These are the emission test and safety valve manually precautions oil-fired boiler, we want to help.

Related Information