boiler supplier

ibr steam boiler means

Operation points premix condensing boiler which, when using condensing boiler, because it takes a special principle advantage of the water cycle, etc. which have some of the heat exchange so as to achieve the desired purpose. Although one condensing boiler price is not too high, and is very simple in operation, and has a good safety performance and so on, but during the operation, the following points need to pay attention to several aspects. First, to do preparatory work before the long-term use is not running or new premix condensing boiler, before starting again with water to clean inside the system, it is extremely important for the preparation of a condensing boiler is, for the next the operation will have a role of great help. And condensing boiler manufacturer reminder should be done in the right order at the time of the official launch of, for example, to open the first circulating pump can ignite. Second, to control the operation of all the details of the process of condensing boilers run them to be able to make it work better, should be kept inside the boiler pressure always is in a stable state, and to control the temperature inside the well, so feel free to do monitoring and surveillance found that there should be any changes to certain adjustments. And condensing boiler manufacturers stressed the need to always put the pipe network in the gas discharged to go, so you can prevent vaporization of good, but also regularly carry out sewage work and to be a reasonable allocation of water inside. Third, to control the pressure in the boiler if the use of the process premix cast aluminum condensing boiler suddenly found liter high pressure inside the boiler, you should immediately identify the reasons, usually because the water temperature is too high gas of caused, so it should be appropriate to reduce the water temperature to solve this problem. There is probably because it did not deal with the dirt is clean and lead to clogging and should therefore be timely to do clean-up work in this area. But if you find a sudden drop in pressure between the condensing boiler, then it should be timely to add water to the boiler, because this is mainly due to lack of water caused. These are the aspects of the operation points premix condensing boiler included, in addition, it should give a rather regular boiler blowdown work, this can be good to avoid accumulation of dirt on the inside and cause clogging phenomenon. And in the process of condensing boiler running, it must control the water and return water temperature difference, the temperature should be controlled at less than 30 degrees, otherwise there will be some security issues.

Hot water boiler and cast iron boilers understand the need of demineralized water: boiler, which is there are many types, such as one of the hot water boiler, ibr steam boiler means and so on these. However, due to the limited length of the article, therefore, it will be for one to be familiar with and understand, so that we can ensure the quality and effectiveness of learning, and will not cause confusion, thus, the emergence of various problems in the use of the boiler. 1. The alcohol-based fuel hot water boiler, which compared with a gas boiler, which is lower running costs? Alcohol-based fuel hot water boiler, which is a hot water boiler, if it is compared with a gas boiler, then, is the running costs of alcohol-based fuel hot water boiler, is lower. Because this kind of hot water boiler is a liquid alcohol as fuel, alcohol-based and uses the combustion burner, in order to ensure good combustion. 2. Why hot water boiler, be sure to use softened water? Hot water boiler specific reasons for the use of demineralized water, because it does not have a scale in the course, so, there are security risks can be avoided boilers, thereby, avoid danger or accident. Therefore, the general in hot water boiler, there will be water softening equipment. If not, then the scale inhibitor is added in a boiler, to achieve the above object.

Hebei Cangzhou issued a "special program on the implementation of standards of governance boiler." Emission standards for boiler treatment and corresponding indication made, as shown in details as follows.

First, the standard standard coal-fired boiler

1, before the end of September 2019, within the city of more than 35 tons of steam / hour ultra-low emission coal-fired boilers complete transformation, emissions of major pollutants to achieve ultra-low emission standards (dust ≤10mg / m³, SO2≤35mg / m³, NOx≤50mg / m³).

Before the end of the year 2/2020, the city eliminated 35 tons of steam / hour and coal-fired boiler, stove and stove operating a small coal stove, achieved within the city 35 steam tons / hour and the boiler "No Coal." Reserved 35 steam tons / hour and coal-fired boiler, stove and stove operating a small coal stove implementation of the special emission standards (dust ≤30mg / m3, SO2≤200mg / m3, NOx≤200mg / m3).

Retention of more than 35 tons of steam / h coal-fired boiler to install air pollution automatic monitoring facilities and networking with the environment department, to install a distributed control system (DCS system), real-time monitoring of pollutant emissions.

Second, gas-fired boiler

1, before the end of September 2019, the city completed two-thirds of the total number of units of low-nitrogen transformation gas boiler above. Among them, the central city of all gas-fired boiler and all the city's industrial and commercial gas-fired boilers to complete a full rebuilding mode low nitrogen.

2, the end of June 2020, the conventional gas boiler should be completed by transformation of a low nitrogen combustion, soot, sulfur dioxide and nitrogen oxide respectively 5mg / m³, 10mg / m³, 30mg / m³.

Third, the task

1, increase clean energy alternatives. In areas not covered by central heating pipe network, and vigorously promote geothermal, wind, solar and other clean energy, in an orderly way from coal to gas and coal to electricity, to change the power-based. In 2020, under the conditions of gas supply has been guaranteed, the city eliminated 35 tons of steam / hour and below the coal-fired boilers.

2, increase the coal management and control efforts. Coal infrared video monitoring devices to increase coal quality sampling efforts, to retain the blast furnace coal-fired boilers to be installed, Hebei coal to meet local standards "Industrial and domestic fuel coal" (DB13 / 208102014) non-coal power generation industry quality indicators .

3, strict new boiler access. Ⅲ class urban area and high-pollution fuel combustion zone ban municipal government designated a ban on new coal-fired boiler, a citywide ban on new 35 steam tons / hour and coal-fired boilers, the new 35 steam tons / hour of coal-fired boilers must in line with the municipal government of central heating planning or construction of industrial parks planning, energy efficiency reached AQSIQ "energy-saving technology supervision and management procedures boiler (TSGG0002-2010)" requirements, encourage the use of "energy efficient boiler promotion List" reached the level of energy efficiency standards boiler, pollutant emissions to meet emission standards require extremely low.

Choice of boiler is critical. The vast majority of boilers sold now are fabricated from welded sheet steel. The steel is usually of fairly low carbon content and of limited life-span. The best choice for long life is always a cast ion boiler. In fact, the massive size of many boilers - especially the biomass burners - ruled them out, as the boiler had to be got into the basement through a window! In fact, a very important point of biomass fired boiler choice is whether you can get it into you boiler room! Don't even consider trying to get a 3/4 ton big boiler down/up a flight of stairs!! Storing fuel near your boiler is very important. You need lots of space, and good access for several tons of fuel. You don't want to be carrying sacks or buckets of stuff from somewhere outside through the snow all winter!

Related Information