boiler supplier

light oil hot water boiler in mauritania

The szs series and wns series of oil and gas boilers produced by ZG boiler are the most widely used. In a big way, it can be widely used in heating, industrial steam and hot water supply, and the company has its own power station. Such as school heating, hotel bath hot water supply, food factory industrial steam supply. These two oil and gas boilers are all fast-assembling boilers with low capital investment and high degree of automation. Customers can choose according to their needs.

Steam boiler pressure gauge should pay attention to matters 1. The rated steam pressure less than 2.45MPa steam boilers, pressure gauge accuracy of not less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure shall not be less than 1.5. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. There are heating and hot water boiler in mauritania bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. On the dial gauge steam boiler should draw a red line to indicate the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, to be sealed lead-sealed after calibration. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1. The surface of the glass or the dial pins; Lead seal, lead seal is broken or exceeds the calibration period; when no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the rank unlimited gauge pointer movement from zero data is out of range pressure layer. Poor; leak or pointer jitter in the meter; other defects affect the accuracy of the pressure gauge. The use of the accumulator: the accumulator for a hydraulic system of the machine intermittently. It may be a low speed motion or intermittent motion of the actuator, the oil reservoir of the hydraulic pump, when rapid movement of the actuator requires a large flow rate, as an auxiliary energy supply to the system together with the hydraulic pump, enabling the pump and the entire hydraulic system miniaturization, to achieve energy saving. Hydraulic shock absorber valve and the opening and closing of rapid mutation load, the system generates a pressure shock, loved one causes vibration and noise and even damage the machine. The accumulator can relax and absorb the impact pressure of the liquid. Accumulators absorb and reduce the pressure pulsation flow pulsation and various hydraulic pumps, thus reducing noise and vibration system. The function of the gas spring having a damper, the vibration can be used to walk between the car body and the wheel and other mechanical absorption. The accumulator may be balance gravity vertical actuator (hydraulic cylinder) and the potential energy absorbing load drop into hydraulic energy storage, while producing speed resistance. When the rising vertical actuator, the accumulator absorbs energy of the original release, and together with the oil pump to the hydraulic cylinders, so as to achieve balance and energy.

State all the more attention to environmental protection, to provide more excellent atmosphere, we respond positively to the country's environmental protection, promote the boiler from coal to gas project. Among the many boiler suppliers, we chose the fast boiler. First, the party quickly done very well in terms of cleaning the boiler, the second is fast side also very comprehensive after-sales involved. The optional gas boiler was used after running fully meet the needs of our pharmaceutical production, both energy-saving and environmental protection, but also a very high thermal efficiency, saved us a lot of fuel costs. --customer feedback

In theory, the boiler fuel consumption under ideal operating conditions = boiler output / fuel calorific value / boiler thermal efficiency.

1. Boiler output refers to boiler power. Steam boilers generally refer to evaporation (t/h), and hot water boilers are thermal power (MW). So far, ZG boiler has been able to produce nine systems and more than 200 products. The wns series horizontal oil and gas boilers produced by ZG boiler have a capacity range of 1-20tph.

2. Boiler thermal efficiency refers to the percentage of effective heat and heat input to the boiler at the same time. Like the wns series of fire tube oil and gas boilers produced by ZG boiler, the thermal efficiency is high, up to 98%.

Related Information