merchant gas boiler vertical

Gas central heating merchant boiler verticals: For a long time I had coal resources are a big country, according to the relevant department statistics national energy use of coal in energy utilization percentage of 70%, the data currently in the world in terms of only four countries is the case (DPRK , Poland, South Africa, China), we can say more than half of the region are due to sub-state pollution, and therefore to change this situation for the benefit of our children and grandchildren is the only solution! This occurs when the fuel gas-fired boiler is that we, step by step out of China's haze cited under the lights, fuel gas-fired boiler is to gradually shift our energy agency oil, gas from coal, clean fuel raw materials such as fuel booster.

Subsequently, the delegation visited the company's merchant boiler vertical cleaning laboratory, technicians demonstrated to the delegation of the company's latest product boiler operation, and use of DCS control system in the laboratory trace data. Mr. Liu to our boiler products to achieve nitrogen oxide (referred to as NOx) emissions below 18 mg or less, is widely used in Beijing APEC venue, the Central Authority and other countries prefix institutions and other international occasions expressed a high degree of praise and encourage.

If a single burner extinguishes, there may also be a deviation in the center of the furnace flame, and the air pressure of the extinguished burner may change. If the fuel supply is interrupted, the oil pressure or pressure indication of the extinguished burner may decrease to zero, while the fuel and gas pressure of other operation burners may rise. After the occurrence of the above situation, the merchant boiler vertical must be handled in a timely manner to ensure the safety of use.

In accordance with article 1.2 13.3.6 to 13.3.8 "merchant boiler vertical design specifications" (GB50041-92): gas-fired boiler provided in the other buildings should be not less than 3 times the amount of ventilation, ventilation hour It does not include the amount of combustion air volume. Dangerous operating room and the like between the gas regulator, the amount of ventilation per hour, should be less than 3 times, when not meet the requirements natural ventilation, mechanical ventilation should be provided, and should be less than 8 air changes per hour accident ventilation times. Fuel pump and reservoir 45 ℃ flash point less than the underground tank of combustible oil, except that natural ventilation, the fuel pump mechanical ventilation 10 air changes per hour should times, six times per hour ventilation should depot mechanical ventilation. The above three are in each room in order to ensure exclusion of air and flammable hydrocarbon disposed a predetermined minimum ventilation rate.

Related Information