boiler supplier

natural gas fired power plant boilers

Four coal-fired fired power plant boilerss precautions to meet a variety of fossil fuels and natural gas sectors of production, often require boiler, the general common is to transform into a coal-fired furnace gas-fired boiler, to change the high fuel costs of coal on the environment cause serious pollution problems, specific issues unique boiler is not a small project, you need to pay attention to a good close links with each transformation in order to avoid failure of transformation, on boiler should be noted that we have to understand the following description. 1, the original boiler demolition work; boiler before carrying out the original host and auxiliary boilers need to be demolished, concrete demolition work carried out by professional staff, in order to more quickly complete the demolition work with but also to prevent the demolition process in the event of any accident; 2, note that pressure capacity of the boiler; small boiler into the gas by the coal-fired, also changed the original negative and positive pressure combustion burner, the process you need to pay special attention throughout the furnace wall the structure and sealing, the sealing function, it might cause the boiler after the transformation could not withstand the pressure and accidents; 3, furnace renovation precautions; when in many cases will change the gas burner, because the fuel mist of poor or incomplete combustion of the fuel gas remaining in the furnace a little mistake will cause fire or explosion, it is carried out after completion of the transformation for an explosion vent installed in an appropriate position to prevent the explosion, while additional ignition flame protection means after the boiler guarantee safe operation; 4, after the transformation of the test; after the completion of high-quality boiler transformation, but also the need for reuse Sophisticated testing to confirm their safety, commonly used test method is boiler pressure after the transformation of high-pressure test, and finally pass a test meet the standard may be considered completed after the entire transformation boilers. Caution visible through major transformation over the course of gas boilers, boiler reconstruction requires not only technical but also need to meet the relevant standards in order to ensure more successful boiler and can be smoothly carried out using, of course, in the transformation of the former users need to analyze the structure of the entire boiler study, confirming boiler renovation project can be re-introduced in order to avoid unnecessary waste.

To ensure the safety of special equipment such as fired power plant boilerss, in normal use, to further promote the comprehensive management of environmental pollution, since April this year, Khorgas Market Supervision Administration of Quality Supervision Bureau for the joint Yili area within the jurisdiction of Khorgas , launched a special safety inspection activities boilers.

Law enforcement officers to be included within the jurisdiction of the major hazard of 12 boiler units of a total of 21 boilers individually conduct a special inspection, focus on examination of the "three implementation, two certified, a test, a plan," the implementation of a detailed view of boiler safety management system, run records.

Test results showed that most of the boiler unit security management more standardized, but there are still some units use boilers run records were incomplete, part of the boiler has to inspection cycle, has been scrapped or dismantled boiler is not write-off and other issues, law enforcement officers to issue on-site boiler sealed, and ordered boiler unit for rectification.

In fact, the fired power plant boilers "coal to gas" fully able to achieve energy, mainly reflected in:

1, high combustion efficiency

How fuel (gas) fired power plant boilers stack height standards should be implemented as specified? Oil, gas boiler chimney of not less than 8 meters, the height of the boiler chimney by specific approval of environmental impact assessment documents OK. When there is a building within a radius of 200m from the new boiler room around the chimney, the chimney should be higher than the tallest building in more than 3m. "Boiler air pollutant emission standards" -GB13271-2014