boiler supplier

power plant boiler for chemical industry

Natural gas power plant boiler for chemical industry Introduction: natural gas gas boiler Description: natural gas boiler glass wool insulation as a whole body type, light weight, good insulation effect, the less heat loss. White color board packaging, nice, closed Haonai corrosion, mechatronics, small footprint, and easy to use. Gas-fired boiler widely used in supermarkets, hospitals, schools, hotels, residential, bath center, fully automated for the user to provide bathing water or heating, domestic hot water.

Horizontal steam power plant boiler for chemical industry Accident Method two: 1, the phenomenon of pipe explosion of a boiler (1) soda can hear the sound of jet when burst pipes, severe obvious explosions. (2) becomes pressurized combustion furnace by the combustion pressure, and ejecting the smoke and steam from the oven door opening and large air leakage at the furnace walls. (3) water flow is not normal, greater than the steam flow. (4) Although increasing water supply, but is often difficult to maintain the water level, steam pressure and reduced. (5) The exhaust gas temperature decreases, the color of white smoke. 6) furnace temperature is lowered, and even fire. 7) draft fan load increased, the current increased. A bottom (8) has a boiler water to flow out, the wet ash hopper ash. 2, the processing squib boiler (1) are not severely leaking tube rupture and can maintain the water level when the accident is not to expand, maintain the operation load can be reduced for a short time, and then start to be standby furnace shutdown. (2) tube rupture when the water level can not be maintained, should an emergency shutdown, but it should not stop the induced draft fan, Boiler Feed should continue to reduce the wall temperature, the accident will not re-expand. (4) if several parallel for the steam boiler, a main steam pipe and the steam should be the parent partition tube boiler accident.

For a long time, the power plant boiler for chemical industry and burner are attributed to two different sectors each R & D re-combination, but the overall performance of the gas boiler, there is a qualitative impact. Fang fast R & D team after two years, estimates adjusted 300 times, breaking the status quo burner and boiler production separate, optimized depth coupled combustion system and heat transfer system architecture, combined boiler and combustion system, combustion system and successfully developed the depth of the heat transfer system coupled "Euromonitor θ5", so that gas-fired boiler into a complete energy system, to achieve a qualitative leap. "Euromonitor θ5" additional air pre-heater, cold air through the heat exchange tubes and the body opening for the flue gas countercurrent heat exchanger, the exhaust gas temperature is lowered while saving fuel; using a condenser, economizer flue gas heat recovery, thermal efficiency of the boiler can be increased by 10%; the use of FGR flue Gas recycling technology and Ultraten wing technology, improve heat transfer efficiency, emissions of nitrogen oxides emissions standards in line with domestic cities.

The steam power plant boiler for chemical industry can't add water to the furnace. What should we do? In the face of this situation, first of all, we should know whether the local water quality is too hard, and there are many places where the water quality is hard over a large volume of water and scale, resulting in the blockage of pipes in steam boilers and the serious possibility of pipe burst. If a steam boiler produces scale due to excessive scale, the heating area of the boiler will be affected, and there will be a large amount of water in the steam. The user said he had softened water equipment and there was no scale in the steam boiler. There should be something wrong with the check valve, and when it opens, it is true that the check valve is stuck in something, and after it has been removed and rinsed with clear water, it will be normal. The water has been added. In the future, use friends to meet this situation, please choose to see if the scale is too much of the pipe blocked, and also to see if the check valve is stuck in something, I hope this content can help to meet this related problems of friends.

Related Information