boiler supplier

sweden 14 ton coal fired steam boiler

Overview of 10 Ton Gas Fired Steam Boiler

10 ton gas fired steam boiler for sale in ZG Boiler is a “D” type double drums water tube boiler, and its furnace hearth is adopted with membrane water wall structure. The 10 ton gas fired steam boiler has a good fuel application, such as light oil, heavy oil, natural gas, liquefied gas, city coal gas and so on. And it has the following advantages: compact structure, small occupation area, good degree of flame; Good thermal insulation performance; With automatic burner, high combustion efficiency; Multiple protection function, safe and reliable operation; ISO9001-2008, IBR and ASME certifications.

Access the PolockGroup Group, the overall strength of the other side of the fast group, boiler quality and after-sales service system are full of praise, and the company signed a three star product - one condensing sweden 14 ton coal fired steam boiler (WNS5-1.25-Y.Q). Up to 104% thermal efficiency of the boiler, the exhaust gas temperature as low as 70 deg.] C and a stable, continuous output of high-quality steam, is valued PolockGroup group. This cooperation is not only a strategic cooperation between the two companies, but also the party pushed forward on the pattern of fast boiler in overseas development, to further promote the party soon Group to expand overseas market a new road.

Coal-fired sweden 14 ton coal fired steam boiler auxiliary equipment which is the result of burning coal-fired steam boiler fuel coal fired boilers to provide steam for industrial production, with the rapid development of the national industrial production, market demand for coal-fired steam boiler gradually increased, boiler in addition to the main components, further include other auxiliary devices, such as coal feeder, induced draft fan and the like. As a supporting auxiliary equipment coal-fired steam boilers, related to an important indicator of whether the normal operation of the boiler, auxiliary equipment and its role following is a small series of analyzes and summarizes the coal-fired steam boiler: 1, fuel supply equipment: Storage and transportation fuels. 2, coal grinding and milling equipment: Pulverized coal milled to a pulverized coal burning and enter the combustion boiler combustion apparatus. 3, the wind blowing apparatus: the air blowing device is defined by the air into the blower means exports coal furnace air preheater after heating and milling. Blower device refers to the boiler flue gas discharged from the chimney draft fan and sent to atmosphere. 4, water supply equipment: water through the water treatment device processing into fired steam from the feed pump. 5, slag, dust removal equipment: Cleaner Equipment refers to the removal of ash from the boiler and carry away equipment, dust removal equipment refers to the removal of fly ash in the boiler flue gas, improved sanitation. 6, the automatic control device: automatic detection, process control, automatic protection and automatic adjustment. Advanced coal-fired steam boiler in a programmable logic controller (PLC) is the central processor of the control system. The control system via the touch screen operation, the boiler automatic control and degree of operational reliability is greatly improved, easier to use and intuitive.

The main characteristics of the indicators boiler What? To demonstrate configuration, capacity, parameter and economical operation of the boiler, etc., generally represented by the following indicators to the basic characteristics of the boiler. A) evaporation industrial boilers evaporation is generally 0.1 ~ 65t / h. For the hot water boiler with a nominal thermal power of its capacity to indicate the size, in units of MW. (Ii) pressure and temperature for saturated steam production boiler, just indicate steam pressure. For the production of superheated sweden 14 ton coal fired steam boiler, the steam temperature of the steam must be marked at the outlet of the superheater, i.e., superheated steam temperature, the unit is deg.] C. For hot water boiler, the hot water temperature has rated outlet and rated the import of sub backwater temperature. With rated thermal power, rated water temperature and the return temperature corresponding to the rated nominal referred circulating water flow of water through the hot water boiler, the unit is t / h. Heating boiler (iii) an evaporator heating surface and the heating surface of the heat generation rate surface evaporation rate or heating rate is an indicator of the intensity of the boiler work, the greater the numerical value, the better the heat transfer, the smaller the amount of metal consumed boiler. Heating surface evaporation rate general industrial boiler is less than 40kg / (m · h); heating surface of the heating rate of hot water boiler is less than 83700kJ / (m · h) iv) the thermal efficiency of the boiler which is an index indicating economical boiler heat, general industrial combustion thermal coal boiler efficiency of around 60% to 82%. Sometimes, in order to measure the heat economy schematically steam boiler, are also commonly used coal or coal water vapor than the ratio expressed as the ratio of the amount of coal in the boiler per unit time over the period of time and the amount of steam production. Coal-water ratio of about the size and type of boiler, coal quality and operation management quality and other factors. Industrial boilers coal-water ratio is generally l: 6 ~ 1: 7.5. Description (a) Evaporation: desired amount of steam produced per hour steam boiler called evaporation, the unit is t / h steam boiler showed that the size of the rated capacity of evaporation, i.e. in boiler design parameters and ensure a certain efficiency. maximum continuous evaporation, also known as the rated output of the boiler (ii) pressure and temperature: the rated pressure steam boiler of the steam at the outlet of the steam or the hot water boiler rated working pressure rated pressure at the outlet of the hot water boiler is called, and He said maximum working pressure, in units of MPa (iii) an evaporator heating surface and the heating surface of the heat generation rate: refers to the heating surface of the pot soft drinks and other heat transfer medium and the flue gas heat exchange area of ​​the pressure receiving member, usually with smoke metal surface area of ​​the gas-side heating area is calculated, in units of square meters. the amount of steam per hour per square meter of the resulting heating surface, called boiler heating surface evaporation rate, in units of kg / (m · h) per hour hot water boiler m² heating surface of heat generated by the heat generation rate is referred to as heating surface, the unit is kJ / (m · h). (Iv) thermal efficiency: thermal efficiency of the boiler is a boiler effective utilization percentage of the heat input and heat boiler per unit time, also called boiler efficiency, [eta] is represented by the symbol.

Related Information