boiler supplier

used boiler 1000 bhp for sale

Boiler continues to operate, the temperature sensor and temperature data are collected continuously transmitted to the controller, as the heating temperature gradually rises to the combustor 53 degrees. At this time, by setting the temperature controller and the current temperature of comparison, determining the water close to the set oven temperature, thus lowering the flame and pilot burner. As the temperature is set closer to 55 ℃, the burner can be based on the actual frequency of the heat demand, precise control of the size of the flame, by gradually close, maintaining the temperature at 55 ℃. When the heat demand changes, the flame will make a corresponding change in the used boiler 1000 bhp for sale only works to maintain the temperature of the state, to avoid unnecessary waste of resources.

Now saving effect intelligent used boiler 1000 bhp for sale equipment, modular design arrangement, the parallel combination of the simple, multi-joint control boiler. Users can produce according to demand, real-time adjustment of the number of operating boilers, to a great extent to meet the different techniques, different steam using steam differentiated, personalized requirements; comprehensive energy saving can reach 30%.

Our jewelry processing company in the automotive production, many processes require energy, to be honest we really a headache on the choice of the used boiler 1000 bhp for sale, thanks met specializes in the research and production of fast square boiler boiler! The purchase of two Taipower hot water boiler, tangible help us save a lot of costs. --customer feedback

3. Close the water level drain cock.

At this time, if there is a water level in the water level table, the boiler is slightly dehydrated, otherwise it is a serious water shortage.

1. When the boiler is slightly short of water, first open the water level steam plug to restore the normal operation of the water level gauge, reduce fuel and air supply, reduce combustion, slowly water to the boiler, and quickly identify the cause of boiler water shortage. When the boiler water level gradually recovers above the minimum safe water level line, the fuel and air supply are increased to restore the normal combustion of the boiler.

2. When the boiler is seriously deficient in water, the boiler should not be flooded. Because the boiler may have been dried, the boiler metal may be in a state of overheating or red burning. Once water is added, serious danger will occur. When the boiler is seriously deficient in water, it should be immediately and immediately shut down according to the prescribed procedures.

Related Information