wns gas hot water boiler power plant

Why gas steam boiler energy saving may be why gas steam boiler energy saving gas steam boiler design pressure should be slightly higher than the high work pressure, and not less than safety valve opening pressure. Design pressure gas furnace using 1.2 to 1.5 times the working pressure; liquid pressure furnace design should take pressure of 1.05 to 1.2 times; Liquid furnace gas and steam outlet pressure differential should be greater than 0.15MPa (1.5kgf / cm2). Temperature gas steam boiler import and export, from the design of both economic and security point of view, to design gas-steam to run a suitable temperature difference in the system, this temperature difference should be less than 30 ℃. Gas steam boiler is a closed loop, the return oil temperature and oil temperature only a 20-30, 20-30 words, only heating the temperature difference can reach temperature gas steam boiler. The steam boiler is added to cold water, the cold water is heated into steam to heat heating device, steam becomes condensed water discharged 60-70 degrees. Therefore, the role of energy saving functions!

In October 2016, my company and the China Dunhuang International Hotel signed a ZWNSL2.1-1.0 / W-Y.Q vacuum condensing gas wns hot water boiler power plant to provide heating and hot water for the hotel. The boiler implementing the response to the national policy of environmental protection requirements and local environmental protection departments on a series of low nitrogen emission standard boiler requirements, in terms of design, manufacture, installation and other sectors have strict checks to ensure that the boiler safe and stable operation.

SZL coal fired chain greate steam boiler for sale

Coal fired boiler design features:

1.By adopting of double wings gas ducts, the fuel gas can go into the front gas tank easily, so the temperature of different front plates can be same. In this way, it can avoid the crackles happening in the plates.

2.Spiral tubes are installed in the drums, which can strengthen the heating transferring efficiency, at the same time, spiral tubes have the ability of dust removal, which can avoid the dust stratification in the tubes.

3.Both of the front and the back arches of the 10t/h series coal fired boiler design adopt mason work of water cool tubes wall structure, which can form permanent arches.

4.Separate adjustable wind chambers. Wind is feed from two sides. It adopts new type crank screw wind adjustment structure, so that the wind adjustment and ventilation cross section proportion is 100%, which can ensure the easy wind adjustment and make it symmetrically.

5.There is push-pull damper dust removal equipment. The damper adopt finish machining cast iron seal structure, thus the secondary combustion distortion and air leaking in the grate is effectively prevented.

Combustion gas treatment unit and a fault, gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer. Second, gas boiler, but spark ignition rods misfire reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Measures are: Clear; first wash, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel); Check tubing and oil filters, insulation equipment ; remove peripheral screw pump, carefully remove the cover inside out oil network, with immersion oil; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing instability reasons: 1, the air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, fuel oil boiler water. Action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; approximately set to about 50 deg.] C; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Processing methods: ① the oil line check valve is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.